- NFC53E-34
ABB NFC53E-34 intermediate relay, manufacturer ID 1SBH131001R3453. It has no main contacts and provides 5 normally open and 3 normally closed auxiliary contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high, with a net weight of 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53E-42
ABB NFC53E-42 intermediate relay, manufacturer ID 1SBH131001R4253. It has five auxiliary contacts NO and three auxiliary contacts NC, with no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz; rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53E-51
ABB NFC53E-51 intermediate relay, manufacturer ID 1SBH131001R5153. It has five auxiliary contacts NO and three auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight is 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53E-80
The ABB NFC53E-80 is an intermediate relay with five auxiliary normally open contacts and three auxiliary normally closed contacts, and no main normally closed contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, with a net weight of 0.351 kg. Rated operational voltage for the auxiliary circuit is 690 V, with a rated frequency of 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 degrees C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally.
- NFC53E-81
The ABB NFC53E-81 is an intermediate relay with manufacturer ID 1SBH131001R8153. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.36 kg. Contact configuration is five auxiliary contacts NO and three auxiliary contacts NC, with no main contacts NC. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53E-84
ABB NFC53E-84 intermediate relay, manufacturer ID 1SBH131001R8453. Auxiliary contact configuration: 5 NO, 3 NC, no main NC contacts. Rated operational voltage for the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W, with rated control circuit voltage 110 V at 50 Hz and 110 to 120 V at 60 Hz. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.357 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53E-85
ABB NFC53E-85 intermediate relay, manufacturer ID 1SBH131001R8553. It has no main contacts (0 NO, 0 NC) and carries 5 auxiliary NO and 3 auxiliary NC contacts. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high, and 0.351 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC53E-86
ABB NFC53E-86 intermediate relay, manufacturer ID 1SBH131001R8653. It has five auxiliary contacts NO and three auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight is 0.351 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.