- AF370-30-00-34
The ABB AF370-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V and 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-3 is 370 A at 380/400 V and 55 °C, and rated operational power AC-3 is 200 kW at 380/400 V. The coil accepts 250 to 500 V at 50 Hz, 60 Hz, or DC. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high; weight is 3.9 kg. Main circuit terminals are bars.
- AF370-30-00-42
The ABB AF370-30-00-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 60 °C, with rated operational power AC-3 of 200 kW at 415 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA.
- AF370-30-00-43
The ABB AF370-30-00-43 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 440 V, 350 A at 500 V, 315 A at 690 V, and 141 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 200 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF370-30-11-11
The ABB AF370-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and an insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Rated operational power in AC-3 is 200 kW at 380/400 V, 415 V, and 440 V, 250 kW at 500 V, and 315 kW at 690 V. The control circuit accepts 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF370-30-11-12
The ABB AF370-30-11-12 is a non-reversing AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, weighing 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 370 A at 415 V and 55 °C, with rated operational power of 200 kW at 415 V. Short-circuit protection uses gG type fuses rated 630 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- AF370-30-11-13
The ABB AF370-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, and rated operational power AC-3 is 200 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection requires gG type fuses rated 630 A.
- AF370-30-11-14
The ABB AF370-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, and rated operational power AC-3 is 200 kW at 415 V. Short-circuit protection uses gG type fuses rated 630 A. Maximum electrical switching frequency in AC-3 is 300 cycles per hour.
- AF370-30-11-31
The ABB AF370-30-11-31 is a 3-pole AC contactor with 3 NO main contacts and 1 NO plus 1 NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 ratings of 370 A at 415 V and 200 kW at 415 V, both at 60 °C. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 140 mm wide, 191 mm deep, and 225 mm high; net weight is 3.9 kg. Conventional free-air thermal current is 600 A per IEC 60947-4-1 at 40 °C. Mechanical durability is 5 million operations. Main terminals are bars; main terminal protection is IP00 and coil terminals IP20 per IEC 60529.