Industrial Automation Parts. Prompt replies from real people.

ABB AF370-30-00-43 3-Phase Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AF370-30-00-43?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF370-30-00-43 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF370-30-00-43
Material Number
1SFL607002R4300
Manufacturer
ABB
Product ID
87754

Get a Free Quote

Request pricing and availability for AF370-30-00-43.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
3.9 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A (1000 V) 60 °C 350 A (1000 V) 70 °C 290 A (690 V) 40 °C 600 A (690 V) 60 °C 500 A (690 V) 70 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW (440 V) 200 kW (500 V) 250 kW (690 V) 315 kW (1000 V) 200 kW (380 / 400 V) 200 kW (220 / 230 / 240 V) 110 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
See all specifications

Product Highlights

  1. Coil Voltage: Rated control circuit voltage 220 to 240 V at 50 Hz and 60 Hz
  2. Main Contacts: 3 normally open main contacts with no normally closed main contacts and no auxiliary contacts
  3. Power Ratings: AC-3 rated operational power 200 kW at 415 V and 440 V, 250 kW at 500 V, 315 kW at 690 V, and 110 kW at 220 to 240 V
  4. Current Ratings: AC-3 rated operational current 370 A at 415 V and 440 V, 350 A at 500 V, 315 A at 690 V, and 141 A at 1000 V
  5. Operating Temperature: Ambient air temperature -40 to 70 °C without thermal overload relay and -25 to 55 °C with thermal overload relay
AF370-30-00-43

Product Information

Technical Specifications

Specifications for AF370-30-00-43

ParameterValue
Product Net Width140 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight3.9 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 400 A (1000 V) 60 °C 350 A (1000 V) 70 °C 290 A (690 V) 40 °C 600 A (690 V) 60 °C 500 A (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 370 A (440 V) 60 °C 370 A (500 V) 60 °C 350 A (690 V) 60 °C 315 A (1000 V) 60 °C 141 A (380400 V) 60 °C 370 A (220230240 V) 60 °C 370 A
Rated Operational Power AC-3 (Pe)(415 V) 200 kW (440 V) 200 kW (500 V) 250 kW (690 V) 315 kW (1000 V) 200 kW (380400 V) 200 kW (220230240 V) 110 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
ParameterValue
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 240 V 60 Hz 220 ... 240 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 20 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 4.5 W Holding at Max. Rated Control Circuit Voltage 60 Hz 20 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 4.5 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Operate TimeBetween Coil De-energization and NO Contact Opening 20 ... 30 ms Between Coil Energization and NO Contact Closing 20 ... 35 ms
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 1x 0.75 ... 2.5 mm² Flexible 2x 0.75 ... 2.5 mm² Solid 1x 1 ... 4 mm² Solid 2x 1 ... 4 mm² Stranded 1x 1 ... 4 mm² Stranded 2x 1 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm Control Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(600 V AC) 520 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 125 hp (220 ... 240 V AC) Three Phase 150 hp (440 ... 480 V AC) Three Phase 300 hp (550 ... 600 V AC) Three Phase 350 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 372 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
Manufacturer ID1SFL607002R4300

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp