- AF370-30-11-42
ABB AF370-30-11-42 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 440 V, 350 A at 500 V, 315 A at 690 V, and 141 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 200 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA.
- AF370-30-11-43
ABB AF370-30-11-43 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 440 V, 350 A at 500 V, 315 A at 690 V, and 141 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 200 kW at 415 V, 440 V, 1000 V, and 380/400 V, 250 kW at 500 V, and 315 kW at 690 V.
- AF370-30-22-11
The ABB AF370-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, 350 A at 500 V and 55 °C, 315 A at 690 V and 55 °C, and 141 A at 1000 V and 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 250 kW at 500 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF370-30-22-12
The ABB AF370-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 380/400 V and 415 V at 55 °C, and rated operational power AC-3 is 200 kW at 380/400 V and 415 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-30-22-13
The ABB AF370-30-22-13 is a three-pole AC contactor with two normally open and two normally closed auxiliary contacts. It is rated for a main circuit voltage of 1000 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, and rated operational power AC-3 is 200 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection requires gG type fuses rated 630 A.
- AF370-30-22-14
The ABB AF370-30-22-14 is a 3-pole, non-reversing AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 370 A at 415 V and 55 °C, and 200 kW at 415 V. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3, and 150 cycles per hour in AC-2/AC-4. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF370-30-22-31
ABB AF370-30-22-31 AC contactor, manufacturer ID 1SFL607002R3122. Three normally open main contacts and no normally closed main contacts, plus two auxiliary NO and two auxiliary NC contacts. Main circuit rated operational voltage 1000 V at 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1 is 600 A at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 60 °C, 315 A at 690 V and 60 °C. Rated operational power AC-3 is 200 kW at 415 V, 315 kW at 690 V. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Mechanical durability is 5 million cycles. Dimensions 160 x 191 x 225 mm, 3.9 kg.
- AF370-30-22-32
The ABB AF370-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 160 mm wide, 191 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 60 °C, and rated operational power AC-3 is 200 kW at 415 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA. Manufacturer ID: 1SFL607002R3222.