- AF370-30-22-33
The ABB AF370-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 370 A at 415 V and 55 °C, and AC-3 rated operational power is 200 kW at 415 V. Short-circuit protection uses gG type fuses rated 630 A. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF370-30-22-34
The ABB AF370-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 195.5 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, and 380/400 V at 55 °C, and 315 A at 690 V at 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 315 kW at 690 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-30-22-42
ABB AF370-30-22-42 is a 3-pole AC contactor, manufacturer ID 1SFL607002R4222. It has 3 main contacts NO, 0 main contacts NC, and 2 auxiliary contacts NO plus 2 auxiliary contacts NC. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Rated operational current AC-3 is 370 A at 380/400 V, 415 V, or 440 V (60 °C), and rated operational power AC-3 is 200 kW at 380/400 V, 415 V, 440 V, and 1000 V. Dimensions are 160 mm wide, 180 mm deep, 225 mm high; net weight 3.9 kg. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C.
- AF370-30-22-43
The ABB AF370-30-22-43 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 440 V, 350 A at 500 V, 315 A at 690 V, and 141 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 200 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Dimensions are 160 mm wide, 180 mm deep, and 225 mm high; weight is 3.9 kg.
- AF370-40-00-11
The ABB AF370-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 525 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 400 A at 1000 V and 40 °C, 350 A at 60 °C, and 290 A at 70 °C; at 690 V it is 525 A at 40 °C, 425 A at 60 °C, and 350 A at 70 °C. Rated operational current AC-3 is 370 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 200 kW at 380/400 V, 415 V, and 440 V, and 110 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; weight is 5.7 kg.
- AF370-40-00-12
The ABB AF370-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 525 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 380/400 V, 415 V, and 440 V, and 110 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-40-00-13
The ABB AF370-40-00-13 is a 4-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL607102R1300. It has four normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 525 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 200 kW at 415 V, 440 V, and 380/400 V, and 110 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF370-40-00-14
The ABB AF370-40-00-14 is a 4-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL607102R1400. It has four normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V and 60 Hz, with a rated insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated operational current AC-3 is 370 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 380/400 V, 415 V, and 440 V, and 110 kW at 220/230/240 V. Dimensions are 184 mm width, 180 mm depth, and 225 mm height; net weight is 5.7 kg.