- AF370-40-00-13
The ABB AF370-40-00-13 is a 4-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL607102R1300. It has four normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 525 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 200 kW at 415 V, 440 V, and 380/400 V, and 110 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF370-40-00-14
The ABB AF370-40-00-14 is a 4-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL607102R1400. It has four normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V and 60 Hz, with a rated insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated operational current AC-3 is 370 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 380/400 V, 415 V, and 440 V, and 110 kW at 220/230/240 V. Dimensions are 184 mm width, 180 mm depth, and 225 mm height; net weight is 5.7 kg.
- AF370-40-11-11
ABB AF370-40-11-11 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 525 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 525 A at 690 V and 40 °C, and 400 A at 1000 V and 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 110 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-40-11-12
The ABB AF370-40-11-12 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 525 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 525 A at 690 V and 40 °C, and AC-3 is 370 A at 415 V and 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 110 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-40-11-13
The ABB AF370-40-11-13 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 525 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 525 A at 690 V and 40 °C, and AC-3 is 370 A at 415 V and 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 110 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-40-11-14
The ABB AF370-40-11-14 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one auxiliary contact NC. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 525 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 415 V, 440 V, and 380/400 V, and 110 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF370-40-22-11
The ABB AF370-40-22-11 is a four-pole AC contactor with four normally open main contacts and no normally closed main contacts. It carries two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V with a rated frequency of 60 Hz. Rated operational power AC-3 is 200 kW at 415 V, 440 V, and 380/400 V, and 110 kW at 220/230/240 V. Conventional free-air thermal current is 525 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg. Main circuit terminals are bars. Coil voltage range is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC.
- AF370-40-22-12
The ABB AF370-40-22-12 is a four-pole AC contactor with four normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 525 A at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 415 V, 440 V, and 380/400 V, and 110 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.