Industrial Automation Parts. Prompt replies from real people.

ABB AF205-30-00-33 3-Phase Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AF205-30-00-33?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF205-30-00-33 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF205-30-00-33
Material Number
1SFL527002R3300
Manufacturer
ABB
Product ID
87728

Get a Free Quote

Request pricing and availability for AF205-30-00-33.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
2.4 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 275 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 70 °C 240 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW (440 V) 132 kW (500 V) 132 kW (690 V) 160 kW (1000 V) 132 kW (380 / 400 V) 110 kW (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
See all specifications

Product Highlights

  1. Wide Control Voltage Range: Rated control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC operation
  2. Main Contacts: 3 normally open main contacts with no normally closed main contacts and no auxiliary contacts
  3. Rated Operational Voltage: Main circuit rated for 1000 V with 50 Hz rated frequency
  4. AC-3 Motor Switching: Rated operational current AC-3 is 205 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 186 A at 500 V, 165 A at 690 V, and 100 A at 1000 V
  5. AC-3 Motor Power: Rated operational power AC-3 is 110 kW at 415 V and 380/400 V, 132 kW at 440 V, 500 V, and 1000 V, 160 kW at 690 V, and 55 kW at 220/230/240 V
  6. Coil Consumption: Pull-in 220 V·A at 50 Hz and 60 Hz, 190 W at DC, holding 7 V·A at 50 Hz and 60 Hz
  7. Operate Time: NO contact closing 25 to 55 ms after coil energization and NO contact opening 37 to 47 ms after coil de-energization
  8. Mechanical Durability: 5 million operating cycles with maximum mechanical switching frequency of 300 cycles per hour
  9. Short-Circuit Protection: gG type fuses rated 400 A
  10. Rated Short-time Withstand Current: 2050 A for 1 s, 1640 A for 10 s, 947 A for 30 s, 670 A for 1 min, and 350 A for 15 min at 40 °C ambient in free air from a cold state
  11. Ambient Air Temperature: -40 to 70 °C close to contactor without thermal overload relay and for storage, -25 to 55 °C close to contactor fitted with thermal overload relay
  12. Maximum Operating Altitude: 3000 m without derating
  13. Terminal Type: Main circuit bars with auxiliary terminals rated IP40
  14. Dimensions and Weight: 105 mm wide, 169.5 mm deep, 196 mm high, 2.4 kg
AF205-30-00-33

Product Information

Technical Specifications

Specifications for AF205-30-00-33

ParameterValue
Product Net Width105 mm
Product Net Depth / Length169.5 mm
Product Net Height196 mm
Product Net Weight2.4 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 275 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 205 A (440 V) 55 °C 205 A (500 V) 55 °C 186 A (690 V) 55 °C 165 A (1000 V) 55 °C 100 A (380400 V) 55 °C 205 A (220230240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)(415 V) 110 kW (440 V) 132 kW (500 V) 132 kW (690 V) 160 kW (1000 V) 132 kW (380400 V) 110 kW (220230240 V) 55 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 400 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
ParameterValue
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage DC 190 W
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 ms Between Coil Energization and NO Contact Closing 25 ... 55 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal TypeMain Circuit: Bars
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(600 V AC) 300 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 30 Hp (200 V AC) Three Phase 60 hp (208 V AC) Three Phase 60 hp (220 ... 240 V AC) Three Phase 30 Hp (220 ... 240 V AC) Three Phase 75 hp (440 ... 480 V AC) Three Phase 75 Hp (440 ... 480 V AC) Three Phase 150 hp (550 ... 600 V AC) Three Phase 100 Hp (550 ... 600 V AC) Three Phase 200 hp
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3707504
Manufacturer ID1SFL527002R3300

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.