- AF205-30-11-11
The ABB AF205-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high, with a net weight of 2.4 kg. Short-circuit protection uses gG type fuses rated 400 A.
- AF205-30-11-12
The ABB AF205-30-11-12 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit voltage of 1000 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high, with a net weight of 2.4 kg. Short-circuit protection uses gG type fuses rated 400 A.
- AF205-30-11-13
The ABB AF205-30-11-13 is a 3-pole AC contactor with three main contacts NO, one auxiliary contact NO, and one auxiliary contact NC. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. The coil operates at 100 to 250 V for 50 Hz, 60 Hz, and DC. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high, with a net weight of 2.4 kg. Mechanical durability is 5 million operations.
- AF205-30-11-14
ABB AF205-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 350 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 205 A at 415 V and 55 °C, and AC-3 rated operational power is 110 kW at 415 V and at 380/400 V. Short-circuit protection is provided by gG type fuses rated 400 A. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high, with a net weight of 2.4 kg.
- AF205-30-11-31
The ABB AF205-30-11-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 60 °C, and rated operational power AC-3 is 110 kW at 415 V. Dimensions are 105 mm wide, 165.5 mm deep, and 196 mm high, with a net weight of 2.4 kg. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA.
- AF205-30-11-32
The ABB AF205-30-11-32 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 205 A at 415 V and 440 V, both at 60 °C, and AC-3 rated operational power is 110 kW at 415 V and 380/400 V. Dimensions are 105 mm wide, 165.5 mm deep, and 196 mm high, with a net weight of 2.4 kg.
- AF205-30-11-33
The ABB AF205-30-11-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 105 mm wide, 169.5 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Short-circuit protection uses gG type fuses rated 400 A. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA.
- AF205-30-11-34
The ABB AF205-30-11-34 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It has a rated operational voltage of 1000 V in the main circuit and a rated frequency of 50 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 350 A at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C, and rated operational power AC-3 is 110 kW at 415 V. Short-circuit protection requires gG type fuses rated 400 A. Dimensions are 105 mm wide, 169.5 mm deep, and 196 mm high, with a net weight of 2.4 kg.