- AF305-30-11-14
The ABB AF305-30-11-14 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF305-30-11-31
The ABB AF305-30-11-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 500 A at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 60 °C, and rated operational power AC-3 is 160 kW at 415 V. Dimensions are 140 mm wide, 191 mm deep, and 225 mm high, with a net weight of 3.9 kg. Rated insulation voltage Ui is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C).
- AF305-30-11-32
The ABB AF305-30-11-32 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 305 A at 415 V and 60 °C, with rated operational power of 160 kW at 415 V. Dimensions are 140 mm wide, 191 mm deep, and 225 mm high, with a net weight of 3.9 kg. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA.
- AF305-30-11-33
The ABB AF305-30-11-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1000 V in the main circuit at 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 305 A at 415 V, 440 V, and 380/400 V at 55 °C, and 290 A at 500 V and 690 V at 55 °C. AC-3 rated operational power is 160 kW at 415 V, 440 V, and 380/400 V, 200 kW at 500 V, and 250 kW at 690 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, weighing 3.9 kg.
- AF305-30-11-34
The ABB AF305-30-11-34 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit terminals are bars. Rated operational voltage is 1000 V for the main circuit at 60 Hz. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Conventional free-air thermal current is 500 A per IEC 60947-4-1 at 40 °C. Mechanical durability is 5 million operating cycles. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg. Rated control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC.
- AF305-30-11-42
The ABB AF305-30-11-42 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It has a rated operational voltage of 1000 V in the main circuit and operates at 50/60 Hz. Rated operational current AC-3 is 305 A at 415 V and 440 V, 290 A at 500 V and 690 V, and 131 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF305-30-11-43
The ABB AF305-30-11-43 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 375 A at 1000 V and 40 °C, and 500 A at 690 V and 40 °C. Rated operational current AC-3 is 305 A at 380/400 V and 60 °C. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Manufacturer ID: 1SFL587002R4311.
- AF305-30-22-11
The ABB AF305-30-22-11 is a 3-pole AC contactor with 3 NO main contacts, 2 NO and 2 NC auxiliary contacts, and bar-type main terminals. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 500 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 305 A at 380/400 V and 55 °C, corresponding to 160 kW; AC-1 rating is 500 A at 690 V and 40 °C. The control circuit accepts 24 to 60 V AC at 50/60 Hz or 20 to 60 V DC. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.