- AF305-30-22-11
The ABB AF305-30-22-11 is a 3-pole AC contactor with 3 NO main contacts, 2 NO and 2 NC auxiliary contacts, and bar-type main terminals. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 500 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 305 A at 380/400 V and 55 °C, corresponding to 160 kW; AC-1 rating is 500 A at 690 V and 40 °C. The control circuit accepts 24 to 60 V AC at 50/60 Hz or 20 to 60 V DC. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF305-30-22-12
The ABB AF305-30-22-12 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 305 A at 415 V and 55 °C, with rated operational power of 160 kW at 415 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg. Short-circuit protection is provided by gG type fuses rated 500 A.
- AF305-30-22-13
The ABB AF305-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, 290 A at 500 V and 55 °C, and 131 A at 1000 V and 55 °C. Rated operational power AC-3 is 160 kW at 415 V and 250 kW at 690 V. Short-circuit protection uses gG type fuses rated 500 A.
- AF305-30-22-14
The ABB AF305-30-22-14 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit of 1000 V and 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 305 A at 415 V and 440 V, and 160 kW at 415 V and 440 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection is specified as gG type fuses at 500 A. Maximum electrical switching frequency is 300 cycles per hour for AC-1 and AC-3.
- AF305-30-22-31
The ABB AF305-30-22-31 is a 3-pole AC contactor with 3 main contacts NO, 2 auxiliary contacts NO, and 2 auxiliary contacts NC. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 305 A at 415 V and 60 °C, with rated operational power of 160 kW at 415 V. The control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high, with a net weight of 3.9 kg. Mechanical durability is 5 million operations. Main terminals are bars; main terminals are IP00 and coil terminals are IP20 per IEC 60529.
- AF305-30-22-32
ABB AF305-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V, 290 A at 500 V and 690 V, and 131 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high; weight is 3.9 kg.
- AF305-30-22-33
The ABB AF305-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a frequency of 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 305 A at 415 V and 55 °C, and 290 A at 690 V and 55 °C. AC-3 operational power is 160 kW at 415 V and 250 kW at 690 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection requires gG type fuses rated 500 A.
- AF305-30-22-34
The ABB AF305-30-22-34 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg.