- AF305-30-22-32
ABB AF305-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V, 290 A at 500 V and 690 V, and 131 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high; weight is 3.9 kg.
- AF305-30-22-33
The ABB AF305-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a frequency of 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 305 A at 415 V and 55 °C, and 290 A at 690 V and 55 °C. AC-3 operational power is 160 kW at 415 V and 250 kW at 690 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection requires gG type fuses rated 500 A.
- AF305-30-22-34
The ABB AF305-30-22-34 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF305-30-22-42
The ABB AF305-30-22-42 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 160 kW at 415 V and 440 V. Dimensions are 160 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF305-30-22-43
ABB AF305-30-22-43 is a 3-phase AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, and 380/400 V at 60 °C, and 290 A at 500 V and 690 V at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, 200 kW at 500 V, and 250 kW at 690 V. Dimensions are 160 mm wide, 180 mm deep, and 225 mm high; net weight 3.9 kg. Manufacturer ID 1SFL587002R4322.
- AF305-40-00-11
The ABB AF305-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a frequency of 50 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg.
- AF305-40-00-12
The ABB AF305-40-00-12 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF305-40-00-13
ABB AF305-40-00-13 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 500 A at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.