- AF140-30-00-42
The ABB AF140-30-00-42 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-00-43
The ABB AF140-30-00-43 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 130 A at 500 V; and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V.
- AF140-30-00B-11
The ABB AF140-30-00B-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-00B-12
The ABB AF140-30-00B-12 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 37 kW at 220/230/240 V, 75 kW at 380/400 V, 415 V, and 690 V, and 90 kW at 440 V and 500 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-00B-13
The ABB AF140-30-00B-13 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF140-30-00B-14
The ABB AF140-30-00B-14 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Corresponding AC-3 rated operational power is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-00B-31
The ABB AF140-30-00B-31 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-00B-32
The ABB AF140-30-00B-32 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 140 A at 415 V and 80 A at 690 V, and AC-3 power ratings of 75 kW at 415 V and 90 kW at 440 V. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, and DC. Mechanical durability is 5 million operating cycles. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, weighing 1.3 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00. Maximum operating altitude without derating is 3000 m.