- AF12B-30-01-14
ABB AF12B-30-01-14 is a 3-pole AC contactor with one built-in normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-1 is 28 A at 690 V and 40 °C or 60 °C, and 24 A at 70 °C. AC-3 ratings include 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. AC-3 power ratings are 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12B-30-01K-14
The ABB AF12B-30-01K-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12B-30-01RT-14
The ABB AF12B-30-01RT-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Terminals are ring-tongue type. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12B-30-10-14
ABB AF12B-30-10-14 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and no normally closed contacts. It uses screw terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.31 kg. Rated operational voltage is 690 V for main and auxiliary circuits at 50/60 Hz. AC-3 rated operational power is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and IEC 60947-5-1, and 600 V per UL/CSA. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12B-30-10K-14
The ABB AF12B-30-10K-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational current AC-1 is 28 A at 690 V and 40 °C; AC-3 ratings include 12 A at 415 V and 12.5 A at 500 V, both at 60 °C. Rated control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Terminals are push-in spring type, IP20. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or two M4 screws placed diagonally.
- AF12B-30-10RT-14
The ABB AF12B-30-10RT-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.32 kg. The control circuit is rated 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Rated operational voltage is 690 V for main and auxiliary circuits. AC-3 ratings include 12 A at 415 V and 5.5 kW at 415 V. Terminals are ring-tongue type. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or by two M4 screws placed diagonally. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-20
The ABB AF12Z-30-01-20 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-21
The ABB AF12Z-30-01-21 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V in AC-3, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V, with AC-3 operational current of 12 A at 415 V and 440 V. Rated operational voltage is 690 V for main and auxiliary circuits, at 50/60 Hz. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight is 0.31 kg. Screw terminals accept main circuit conductors from 1 to 6 mm². Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.