- AF12Z-30-01-20
The ABB AF12Z-30-01-20 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-21
The ABB AF12Z-30-01-21 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V in AC-3, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V, with AC-3 operational current of 12 A at 415 V and 440 V. Rated operational voltage is 690 V for main and auxiliary circuits, at 50/60 Hz. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight is 0.31 kg. Screw terminals accept main circuit conductors from 1 to 6 mm². Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-22
The ABB AF12Z-30-01-22 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 12 A at 415 V and 60 °C, and 9 A at 690 V and 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-23
The ABB AF12Z-30-01-23 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-1 is 28 A at 690 V and 40 °C or 60 °C, and 24 A at 70 °C. Rated operational current AC-3 is 12 A at 415 V and 60 °C, with rated operational power AC-3 of 5.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-30
The ABB AF12Z-30-01-30 is an AC contactor with manufacturer ID 1SBL156001R3001. It has three normally open main contacts, no normally open auxiliary contacts, and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm width, 97 mm depth, and 86 mm height, weighing 0.43 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-01K-20
ABB AF12Z-30-01K-20 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. AC-3 ratings include 12 A at 415 V and 5.5 kW at 415 V, and 9 A and 7.5 kW at 690 V, at 60 °C. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL156005R2001.
- AF12Z-30-01K-21
The ABB AF12Z-30-01K-21 is a 3-pole AC contactor, manufacturer ID 1SBL156005R2101. It has three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.315 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-01K-22
The ABB AF12Z-30-01K-22 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, and 7.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.