- AF12Z-30-01-23
The ABB AF12Z-30-01-23 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-1 is 28 A at 690 V and 40 °C or 60 °C, and 24 A at 70 °C. Rated operational current AC-3 is 12 A at 415 V and 60 °C, with rated operational power AC-3 of 5.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01-30
The ABB AF12Z-30-01-30 is an AC contactor with manufacturer ID 1SBL156001R3001. It has three normally open main contacts, no normally open auxiliary contacts, and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm width, 97 mm depth, and 86 mm height, weighing 0.43 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-01K-20
ABB AF12Z-30-01K-20 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. AC-3 ratings include 12 A at 415 V and 5.5 kW at 415 V, and 9 A and 7.5 kW at 690 V, at 60 °C. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL156005R2001.
- AF12Z-30-01K-21
The ABB AF12Z-30-01K-21 is a 3-pole AC contactor, manufacturer ID 1SBL156005R2101. It has three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.315 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-01K-22
The ABB AF12Z-30-01K-22 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, and 7.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01K-23
The ABB AF12Z-30-01K-23 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12Z-30-01K-30
The ABB AF12Z-30-01K-30 is a 3-pole AC contactor with one built-in normally closed auxiliary contact and push-in spring terminals. It measures 45 mm wide, 97 mm deep, and 92.3 mm high, and weighs 0.435 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-1 is 28 A at 690 V and 40 °C, and 24 A at 690 V and 70 °C. Rated operational power AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-10-20
ABB AF12Z-30-10-20 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 28 A at 690 V at 40 °C and 60 °C, and 24 A at 70 °C. AC-3 ratings include 12 A at 415 V and 9 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL156001R2010.