- AF12Z-30-10-20
ABB AF12Z-30-10-20 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 28 A at 690 V at 40 °C and 60 °C, and 24 A at 70 °C. AC-3 ratings include 12 A at 415 V and 9 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL156001R2010.
- AF12Z-30-10-21
The ABB AF12Z-30-10-21 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It has screw terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Terminal protection is IP20. DIN rail mounting is TH35-15 or TH35-7.5 per IEC 60715.
- AF12Z-30-10-22
ABB AF12Z-30-10-22 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-1 is 28 A at 690 V and 40 °C or 60 °C, and 24 A at 70 °C. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-10-23
The ABB AF12Z-30-10-23 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a control voltage range of 100-250 V AC/DC and screw terminals. Rated operational power in AC-3 is 5.5 kW at 380/400 V, 415 V, and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.31 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-10-30
The ABB AF12Z-30-10-30 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It is intended for 24 VDC control. Dimensions are 45 mm wide, 97 mm deep, and 86 mm high, with a net weight of 0.43 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 power ratings are 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V.
- AF12Z-30-10K-20
The ABB AF12Z-30-10K-20 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It is rated for a control voltage range of 12-20 V DC and uses push-in spring terminals. Per IEC/EN 60947-4-1, AC-3 rated operational power is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. AC-3 rated operational current is 12 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight is 0.315 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-10K-21
The ABB AF12Z-30-10K-21 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Terminals are push-in spring type. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12Z-30-10K-22
ABB AF12Z-30-10K-22 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.315 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with 50/60 Hz rated frequency. Rated operational current AC-3 is 12 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Corresponding AC-3 rated power is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.