- AF40B-30-11-11
The ABB AF40B-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, and weighs 1.01 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 60 °C, and rated operational power AC-3 is 18.5 kW at 400 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF40B-30-11-12
The ABB AF40B-30-11-12 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 111 mm deep, and 125.5 mm high, and weighs 1.01 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40B-30-11-13
ABB AF40B-30-11-13 AC contactor, manufacturer ID 1SBL347061R1311. It has three normally open main contacts and one normally open plus one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 67 mm wide, 111 mm deep, and 125.5 mm high; net weight 0.99 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40B-30-11-14
The ABB AF40B-30-11-14 is a 3-pole AC contactor with three main contacts NO, no main contacts NC, and one auxiliary contact NO plus one auxiliary contact NC. It uses screw terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 or 2 x M6 screws placed diagonally. Dimensions are 67 mm wide, 111 mm deep, and 125.5 mm high, with a net weight of 0.99 kg. Rated operational voltage is 690 V for main and auxiliary circuits at 50/60 Hz. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40B-40-00-11
ABB AF40B-40-00-11 AC contactor, manufacturer ID 1SBL347261R1100. It has four normally open main contacts and no normally closed main or auxiliary contacts. Dimensions are 70 mm wide, 113.5 mm deep, and 125.5 mm high, with a net weight of 1.21 kg. The main circuit is rated 690 V at 50/60 Hz, with control circuit frequency 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40B-40-00-12
The ABB AF40B-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz and carries 105 A conventional free-air thermal current per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 40 A at 415 V and 440 V, and AC-3 rated operational power is 18.5 kW at 380/400 V. Screw terminals are provided, with main circuit connecting capacity for rigid stranded conductors of 6 to 35 mm². Dimensions are 70 mm wide, 113.5 mm deep, and 125.5 mm high; net weight is 1.21 kg. Applicable standards include IEC/EN 60947-4-1 and UL 60947-4-1.
- AF40B-40-00-13
The ABB AF40B-40-00-13 is an AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 690 V, with 50/60 Hz operation on both control and main circuits. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, both at 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 18.5 kW at 380/400 V. Dimensions are 70 mm wide, 113.5 mm deep, and 125.5 mm high; net weight is 1.27 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF40B-40-00-14
ABB AF40B-40-00-14 is an AC contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, and weighs 1.16 kg. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. AC-3 power ratings include 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.