Industrial Automation Parts. Prompt replies from real people.

ABB AF40B-40-00-11 AC contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AF40B-40-00-11?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF40B-40-00-11 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF40B-40-00-11
Material Number
1SBL347261R1100
Manufacturer
ABB
Product ID
85240

Get a Free Quote

Request pricing and availability for AF40B-40-00-11.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.21 kg
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW (380 / 400 V) 18.5 kW (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
See all specifications

Product Highlights

  1. Main Contacts: 4 normally open (NO) main contacts with no normally closed or auxiliary contacts
  2. Coil Voltage: Rated control circuit voltage of 24 to 60 V at 50/60 Hz and 20 to 60 V DC
  3. Current Ratings: Conventional free-air thermal current of 105 A and AC-1 rated operational current of 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C at 690 V
  4. Power Ratings: AC-3 rated operational power of 22 kW at 415, 440, 500, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V
  5. Mounting and Dimensions: DIN rail TH35-15 or diagonal M4/M6 screw mounting, 70 mm wide, 113.5 mm deep, 125.5 mm high, and 1.21 kg
AF40B-40-00-11

Product Information

Technical Specifications

Specifications for AF40B-40-00-11

ParameterValue
Product Net Width70 mm
Product Net Depth / Length113.5 mm
Product Net Height125.5 mm
Product Net Weight1.21 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Control Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 40 A (440 V) 60 °C 40 A (500 V) 60 °C 35 A (690 V) 60 °C 25 A (380400 V) 60 °C 40 A (220230240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)(415 V) 22 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW (380400 V) 18.5 kW (220230240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V acc. to UL/CSA 600 V
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 4 V·A Average Holding Value DC 2 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm² Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 0 mm Control Circuit 10 mm Main Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
Continuous Current Rating NEMA0 A
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 60 A
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAControl Circuit 11 in·lb Main Circuit 35 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Shock and Vibration Withstand acc. to IEC 61373Category 1, Class B
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
Manufacturer ID1SBL347261R1100

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?