Q1Can you supply the ABB OT125F3?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT125F3 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT125F3
Material Number
1SCA105033R1001
Manufacturer
ABB
Product ID
87565

Get a Free Quote

Request pricing and availability for OT125F3.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
0.36 kg
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
See all specifications

Product Highlights

  1. Rated Current: 125 A conventional free-air thermal current (Ith) at 40 °C and 125 A fully enclosed thermal current (Ithe)
  2. Operational Ratings: 3-pole front-operated switch with AC-21A and AC-22A ratings of 125 A at 380–415 V, 500 V, and 690 V, and AC-23A ratings of 90 A at 380–415 V, 70 A at 500 V, and 50 A at 690 V
  3. Short-Circuit Withstand: 3.6 kA rated short-circuit making capacity at 690 V, 2.5 kA short-time withstand current for 1 s, and conditional short-circuit current up to 50 kA at 415 V with a 125 A fuse
  4. Terminations and Mounting: Screw terminals accept 10–70 mm² Cu conductors, base mounting, 6 N·m tightening torque, 18–21 mm wire stripping length, and a 4 mm hexagon screwdriver is recommended
  5. Dimensions and Protection: 70 mm wide, 100 mm high, 74 mm deep, 0.36 kg, front IP20, pollution degree 3, rated insulation voltage 750 V, rated impulse withstand voltage 8 kV, and mechanical durability of 20,000 operations
OT125F3

Product Information

Technical Specifications

Specifications for OT125F3

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301264D0201
Pollution Degree3
Product Net Width70 mm
Product Net Height100 mm
Product Net Depth / Length74 mm
Product Net Weight0.36 kg
Cable Cross-SectionCu 10 ... 70 mm²
Connecting Capacity Main CircuitFlexible 1x Cu 10…70 mm² Stranded 1x Cu 10…70 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 125 A
Conventional Thermal Current (Ithe)Fully Enclosed 125 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Handle TypeKnob Handle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles3P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 6.3 W
Rated Conditional Short-Circuit Current (Inc)(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 90 A (500 V) 70 A (690 V) 50 A
ParameterValue
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 2.5 kA
Recommended Screw DriverMain Circuit Hexagon 4
Special FunctionsNo
StandardsIEC 60947-3
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 6 N·m
Wire Stripping LengthMain Circuit 18-21 mm
Maximum Operating Voltage UL/CSA600 V
Ampere Rating100 A
Horsepower Rating UL/CSA(acc. to UL 200 V) 25 Hp (acc. to UL 480 V) 50 Hp (acc. to UL 240 V) 30 Hp (acc. to UL 208 V) 25 Hp (acc. to UL 600 V) 50 Hp
Wire Stripping LengthMain Circuit 18-21 mm
Recommended Screw DriverMain Circuit Hexagon 4
Tightening Torqueacc. IEC 60947-1 6 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5290 >> Disconnect switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3601409
E-Number (Norway)4363532
E-Number (Sweden)3170943
Manufacturer ID1SCA105033R1001