Industrial Automation Parts. Prompt replies from real people.

ABB OT125F6 Disconnect Switch

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB OT125F6?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB OT125F6 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
OT125F6
Material Number
1SCA105057R1001
Manufacturer
ABB
Product ID
83939

Get a Free Quote

Request pricing and availability for OT125F6.

More parts to source? Send your whole list in one enquiry

Key specifications

Degree of Protection
Front IP20
Product Net Weight
1.1 kg
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
See all specifications

Product Highlights

  1. Electrical Ratings: 6-pole isolating switch rated 125 A at 380-415 V, 500 V, and 690 V for AC-21A and AC-22A, with AC-23A ratings of 90 A at 380-415 V, 70 A at 500 V, and 50 A at 690 V
  2. Switching Capacity: Rated operational power AC-23A up to 45 kW at 400-415 V, 500 V, and 690 V, rated insulation voltage 750 V, rated impulse withstand voltage 8 kV, and rated short-time withstand current 2.5 kA for 1 s
  3. Terminations and Mounting: Screw terminals accept Cu cable cross-sections of 10 to 70 mm², tightening torque 6 N·m, wire stripping length 18-21 mm, base mounting, front-operated mechanism on top of the switch, knob handle and shaft not included
  4. Protection and Durability: Front IP20 degree of protection, pollution degree 3, mechanical durability of 20000 operating cycles, and power loss of 6.3 W per pole at rated operating conditions
  5. Compliance and Dimensions: Complies with IEC 60947-3, dimensions 140 mm width x 100 mm height x 86 mm depth, net weight 1.1 kg, maximum operating voltage UL/CSA 600 V, and UL/CSA horsepower ratings up to 50 Hp
OT125F6

Product Information

Technical Specifications

Specifications for OT125F6

ParameterValue
Degree of ProtectionFront IP20
Environmental Information1SCC301264D0201
Pollution Degree3
Product Net Width140 mm
Product Net Height100 mm
Product Net Depth / Length86 mm
Product Net Weight1.1 kg
Cable Cross-SectionCu 10 ... 70 mm²
Connecting Capacity Main CircuitFlexible 1x Cu 10…70 mm² Stranded 1x Cu 10…70 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 125 A
Conventional Thermal Current (Ithe)Fully Enclosed 125 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Handle TypeKnob Handle and shaft not included
Lock TypeNo
Mechanical Durability20000
Mounting TypeBase mounting
Number of Poles6P
Operating ModeFront operated
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out Bottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 6.3 W
Rated Conditional Short-Circuit Current (Inc)(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
ParameterValue
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 90 A (500 V) 70 A (690 V) 50 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 2.5 kA
Recommended Screw DriverMain Circuit Hexagon 4
Special FunctionsNo
StandardsIEC 60947-3
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening Torqueacc. IEC 60947-1 6 N·m
Wire Stripping LengthMain Circuit 18-21 mm
Maximum Operating Voltage UL/CSA600 V
Ampere Rating100 A
Horsepower Rating UL/CSA(acc. to UL 200 V) 25 Hp (acc. to UL 480 V) 50 Hp (acc. to UL 240 V) 30 Hp (acc. to UL 208 V) 25 Hp (acc. to UL 600 V) 50 Hp
Wire Stripping LengthMain Circuit 18-21 mm
Recommended Screw DriverMain Circuit Hexagon 4
Tightening Torqueacc. IEC 60947-1 6 N·m
Object Classification CodeQ
ETIM 8EC000216 - Switch disconnector
ETIM 9EC000216 - Switch disconnector (low voltage)
UNSPSC39122233
IDEA Granular Category Code (IGCC)5293 >> Switch disconnector
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)3601415
E-Number (Norway)4363568
Manufacturer ID1SCA105057R1001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.