Industrial Automation Parts. Prompt replies from real people.

ABB CM-SRS.11P Current Monitoring Relay

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB CM-SRS.11P?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB CM-SRS.11P cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
CM-SRS.11P
Material Number
1SVR740840R0200
Manufacturer
ABB
Product ID
87406

Get a Free Quote

Request pricing and availability for CM-SRS.11P.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.137 kg
Rated Control Supply Voltage (Us)
24 ... 240 V AC/DC
Rated Operational Current AC-12 (Ie)
(230 V) 4 A
Rated Impulse Withstand Voltage (Uimp)
Measuring Circuit / Output Circuit 6 kV Output Circuit 1 / Output Circuit 2 4 kV Supply Circuit / Measuring Circuit 6 kV Supply Circuit / Output Circuit 4 kV
Degree of Protection
Housing IP50 Terminals IP20
See all specifications

Product Highlights

  1. Monitoring Function: Configurable for overcurrent or undercurrent monitoring
  2. Measuring Ranges: Three selectable ranges of 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A
  3. Supply Voltage: 24 to 240 V AC/DC rated control supply voltage
  4. Output Contact: One changeover (SPDT) contact rated 4 A at 230 V AC (AC-12) and 4 A at 24 V DC (DC-12), with a minimum switching capacity of 24 V 10 mA
  5. Durability: Mechanical durability of 30 million cycles and electrical durability of 100000 cycles at AC-12
  6. Mounting and Connection: DIN rail mounting per IEC 60715 (TH35-15 and TH35-7.5) with screwless terminals accepting 2x 0.5 to 1.5 mm² and 8 mm stripping length
  7. Dimensions and Protection: 22.5 mm wide, housing IP50 and terminals IP20, flammability V-0 per UL94
  8. Ambient Conditions: Operating temperature -20 to +60 °C, storage -40 to +85 °C, maximum operating altitude 2000 m without derating
  9. Standards: Complies with IEC/EN 60255-27, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, and CAN/CSA C22.2 No.14
CM-SRS.11P

Product Information

Technical Specifications

Specifications for CM-SRS.11P

ParameterValue
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.137 kg
FunctionOver- or undercurrent monitoring
Measuring Range3 ... 30 mA 10 ... 100 mA 0.1 ... 1 A
Rated Control Supply Voltage (Us)24 ... 240 V AC/DC
Output1 c/o (SPDT) contact
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V 10 mA
Rated Impulse Withstand Voltage (Uimp)Measuring CircuitOutput Circuit 6 kV Output Circuit 1Output Circuit 2 4 kV Supply CircuitMeasuring Circuit 6 kV Supply CircuitOutput Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring CircuitOutput Circuit 600 V Output Circuit 1Output Circuit 2 250 V Supply CircuitMeasuring Circuit 600 V Supply CircuitOutput Circuit 250 V
Degree of ProtectionHousing IP50 Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
ParameterValue
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical Durability30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm² Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² Flexible 2x 0.5 ... 1.5 mm² Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14 IEC/EN 63000 IEC/EN 60255-27 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Ambient Air TemperatureOperation -20 ... +60 °C Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Object Classification CodeB
ETIM 7EC001440 - Current monitoring relay
ETIM 8EC001440 - Current monitoring relay
ETIM 9EC001440 - Current monitoring relay
eClassV11.0 : 27371802
UNSPSC39122332
E-Number (Finland)2712300
E-Number (Norway)4188047
E-Number (Sweden)3860648
Manufacturer ID1SVR740840R0200

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.