- CM-SRS.11S
The ABB CM-SRS.11S is an intermediate relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR730841R1200. It measures 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A, and is rated for a 220 to 240 V AC control supply voltage. Output is one changeover (SPDT) contact via screw terminals, with rated operational currents of 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighing 0.161 kg. Housing protection is IP50 and terminals IP20.
- CM-SRS.12S
The ABB CM-SRS.12S is an intermediate relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR730841R1300. It measures 0.3 to 1.5 A, 1 to 5 A, and 3 to 15 A, and is powered by a rated control supply voltage of 220 to 240 V AC. Output is one changeover (SPDT) contact via screw terminals, rated 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13, with a minimum switching capacity of 24 V, 10 mA. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.168 kg, and has housing protection IP50 and terminal protection IP20.
- CM-SRS.21P
The ABB CM-SRS.21P is a single-function current monitoring relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR740840R0400. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Tripping delay is 0 s or 0.1 to 30 s (ON). Rated control supply voltage is 24 to 240 V AC/DC. Output is two changeover (SPDT) contacts with screwless terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.141 kg. Housing protection is IP50 and terminals IP20.
- CM-SRS.21S
The ABB CM-SRS.21S is an intermediate relay for over- or undercurrent monitoring, with manufacturer ID 1SVR730840R0400. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Tripping delay is 0 s or 0.1 to 30 s. Rated control supply voltage is 24 to 240 V AC/DC. Output is two changeover (SPDT) contacts with screw terminals. Rated operational currents are 4 A AC-12 and 3 A AC-15 at 230 V, and 4 A DC-12 and 2 A DC-13 at 24 V. Dimensions are 22.5 x 85.6 x 103.7 mm; net weight 0.152 kg. Housing protection is IP50, terminals IP20. Ambient operating temperature is -20 to +60 °C.
- CM-SRS.22S
ABB CM-SRS.22S intermediate relay for over- or undercurrent monitoring, manufacturer ID 1SVR730841R0500. Measuring ranges are 0.3 ... 1.5 A, 1 ... 5 A, and 3 ... 15 A. Tripping delay is 0 s or 0.1 ... 30 s (ON). Rated control supply voltage is 110 ... 130 V AC. Output is 2 c/o (SPDT) contacts with screw terminals. Rated operational currents are AC-12 (230 V) 4 A, AC-15 (230 V) 3 A, DC-12 (24 V) 4 A, and DC-13 (24 V) 2 A. Minimum switching capacity is 24 V 10 mA. Dimensions are 22.5 mm width, 85.6 mm height, and 103.7 mm depth; net weight 0.181 kg. Housing protection is IP50 and terminals IP20, overvoltage category III, pollution degree 3.
- CM-SRS.M1P
ABB CM-SRS.M1P intermediate relay, order code 1SVR740840R0600, is a current monitoring relay for over- or undercurrent monitoring. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Start-up delay and tripping delay (ON) are each selectable as 0 s or 0.1 to 30 s. Rated control supply voltage is 24 to 240 V AC/DC. Output is two changeover (SPDT) contacts with selectable operating principle. Connections use screwless terminals. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.142 kg. Housing protection is IP50 and terminal protection is IP20.
- CM-SRS.M1S
The ABB CM-SRS.M1S is an intermediate relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR730840R0600. It measures 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A, with selectable start-up delay of 0 s or 0.1 to 30 s and tripping delay (ON) of 0 s or 0.1 to 30 s. Rated control supply voltage is 24 to 240 V AC/DC. Output is two changeover (SPDT) contacts with selectable operating principle. Screw terminals are used. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighing 0.153 kg. Housing protection is IP50 and terminals IP20, with overvoltage category III and pollution degree 3.
- CM-SRS.M2S
The ABB CM-SRS.M2S is an intermediate relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR730840R0700. It offers three measuring ranges: 0.3 to 1.5 A, 1 to 5 A, and 3 to 15 A. Start-up and tripping delays are selectable as 0 s or 0.1 to 30 s. The rated control supply voltage is 24 to 240 V AC/DC. Output is two c/o (SPDT) contacts with selectable operating principle. Rated operational currents include 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Screw terminals are used. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.155 kg.