- CM-SRS.22S
ABB CM-SRS.22S intermediate relay for over- or undercurrent monitoring, manufacturer ID 1SVR730841R0500. Measuring ranges are 0.3 ... 1.5 A, 1 ... 5 A, and 3 ... 15 A. Tripping delay is 0 s or 0.1 ... 30 s (ON). Rated control supply voltage is 110 ... 130 V AC. Output is 2 c/o (SPDT) contacts with screw terminals. Rated operational currents are AC-12 (230 V) 4 A, AC-15 (230 V) 3 A, DC-12 (24 V) 4 A, and DC-13 (24 V) 2 A. Minimum switching capacity is 24 V 10 mA. Dimensions are 22.5 mm width, 85.6 mm height, and 103.7 mm depth; net weight 0.181 kg. Housing protection is IP50 and terminals IP20, overvoltage category III, pollution degree 3.
- CM-SRS.M1P
ABB CM-SRS.M1P intermediate relay, order code 1SVR740840R0600, is a current monitoring relay for over- or undercurrent monitoring. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Start-up delay and tripping delay (ON) are each selectable as 0 s or 0.1 to 30 s. Rated control supply voltage is 24 to 240 V AC/DC. Output is two changeover (SPDT) contacts with selectable operating principle. Connections use screwless terminals. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.142 kg. Housing protection is IP50 and terminal protection is IP20.
- CM-SRS.M1S
The ABB CM-SRS.M1S is an intermediate relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR730840R0600. It measures 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A, with selectable start-up delay of 0 s or 0.1 to 30 s and tripping delay (ON) of 0 s or 0.1 to 30 s. Rated control supply voltage is 24 to 240 V AC/DC. Output is two changeover (SPDT) contacts with selectable operating principle. Screw terminals are used. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighing 0.153 kg. Housing protection is IP50 and terminals IP20, with overvoltage category III and pollution degree 3.
- CM-SRS.M2S
The ABB CM-SRS.M2S is an intermediate relay for over- or undercurrent monitoring, identified by manufacturer ID 1SVR730840R0700. It offers three measuring ranges: 0.3 to 1.5 A, 1 to 5 A, and 3 to 15 A. Start-up and tripping delays are selectable as 0 s or 0.1 to 30 s. The rated control supply voltage is 24 to 240 V AC/DC. Output is two c/o (SPDT) contacts with selectable operating principle. Rated operational currents include 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Screw terminals are used. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.155 kg.
- CM-TCN.011P
The ABB CM-TCN.011P intermediate relay (manufacturer ID 1SVR760740R0110) provides overtemperature, undertemperature, and combined over/undertemperature monitoring. It accepts PT100, PT1000, PTC, NTC, and bimetal switch sensors over a measuring range of -200 to +850 °C. The rated control supply voltage is 24 to 240 V AC/DC, with 50 Hz, 60 Hz, and DC supply circuits. Output is three configurable 1 c/o contacts; rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V 100 mA. The unit measures 45 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.265 kg, uses screwless terminals, and has housing protection IP50 and terminal protection IP20.
- CM-TCN.011S
The ABB CM-TCN.011S is a DIN-rail intermediate relay for temperature monitoring, identified by manufacturer ID 1SVR750740R0110. It accepts PT100, PT1000, PTC, NTC, and bimetal switch sensors, with a measuring range of -200 to +850 °C. Functions include overtemperature, undertemperature, and combined over- and undertemperature monitoring. The output is three configurable 1 c/o contacts via screw terminals. Rated control supply voltage is 24 to 240 V AC/DC, with supply circuit 50 Hz, 60 Hz, or DC. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Dimensions are 45 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.265 kg.
- CM-TCN.012P
The ABB CM-TCN.012P is an intermediate relay for temperature monitoring, identified by manufacturer ID 1SVR760740R0120. It performs overtemperature, undertemperature, and combined over- and undertemperature monitoring. The measuring range is -200 to +850 °C, and supported sensor types are PT100, PT1000, PTC, NTC, and bimetal switch. Rated control supply voltage is 24 to 240 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, and DC. Output is three configurable 1 c/o contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V 100 mA. Dimensions are 45 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.27 kg. Terminals are screwless. Housing protection is IP50, terminals IP20, overvoltage category III.
- CM-TCN.012S
ABB CM-TCN.012S temperature monitoring relay, order code 1SVR750740R0120, for overtemperature, undertemperature, and combined over/undertemperature monitoring. Measuring range -200 to +850 °C with PT100, PT1000, PTC, NTC, or bimetal switch sensors. Rated control supply voltage 24 to 240 V AC/DC, 50 Hz, 60 Hz, or DC. Three configurable 1 c/o output contacts, screw terminals. Rated operational current AC-12 (230 V) 4 A, AC-15 (230 V) 3 A, DC-12 (24 V) 4 A, DC-13 (24 V) 2 A. Dimensions 45 x 85.6 x 103.7 mm, net weight 0.27 kg. Housing IP50, terminals IP20. Ambient operating temperature -25 to +60 °C. DIN rail mounting per IEC 60715.