- AF26ZB-30-00RT-21
The ABB AF26ZB-30-00RT-21 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V with a rated impulse withstand voltage of 6 kV and an insulation voltage of 690 V according to IEC 60947-4-1. Rated operational current AC-3 is 26 A at 415 V and 60 °C, and rated operational power AC-3 is 11 kW at 415 V. The control circuit operates at 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or on two M4 screws placed diagonally. Terminal type is ring-tongue. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26ZB-30-00RT-22
The ABB AF26ZB-30-00RT-22 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.36 kg. The control circuit accepts 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Rated operational voltage for the main circuit is 690 V, with a rated impulse withstand voltage of 6 kV. Rated operational power in AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V, at 60 degrees C. Terminals are ring-tongue type. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26ZB-30-00RT-23
The ABB AF26ZB-30-00RT-23 is a 3-pole AC contactor with ring-tongue terminals and three normally open main contacts. It is rated 690 V in the main circuit and 100 to 250 V at 50/60 Hz or DC in the control circuit. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C, and AC-3 rated operational power is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V. The contactor measures 45 mm wide, 86 mm deep, and 86 mm high, weighs 0.36 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 or on two diagonal M4 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26ZB-40-00-21
The ABB AF26ZB-40-00-21 is a 4-pole AC contactor with four normally open main contacts, no normally closed main contacts, and no auxiliary contacts. Screw terminals are used for main and control connections. The main circuit is rated 690 V, and the contactor is rated 11 kW at 400 V AC-3. Control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.41 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF26ZB-40-00-22
The ABB AF26ZB-40-00-22 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.41 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, corresponding to 11 kW at 400 V. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AF26ZB-40-00-23
The ABB AF26ZB-40-00-23 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It operates on a control circuit of 100-250 V at 50/60 Hz and DC, with built-in surge protection. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 60 °C, and 10.5 A at 690 V and 60 °C. Rated operational power AC-3 is 11 kW at 400 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, weighing 0.41 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF26ZB-40-00RT-23
The ABB AF26ZB-40-00RT-23 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 22 A at 380/400 V and 11 kW at 400 V, and AC-1 ratings of 45 A at 40 °C, 40 A at 60 °C, and 32 A at 70 °C at 690 V. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 86 mm H x 45 mm W x 101 mm D, weight 0.39 kg, ring-tongue terminals, DIN rail or 2 x M4 screw mounting. Operating ambient temperature is -40 to +70 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 61373 Category 1 Class B, and applicable parts of IEC 60077-1, IEC 60077-2, and EN 50155.
- AF2850-30-11-70
The ABB AF2850-30-11-70 is a 3-pole AC contactor with one normally open and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 2850 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2850 A at 40 °C, 2600 A at 55 °C, and 2300 A at 70 °C, at both 690 V and 1000 V. Rated insulation voltage is 1000 V, and rated impulse withstand voltage is 8 kV. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg.