Industrial Automation Parts. Prompt replies from real people.

ABB AF2850-30-11-70 3-Pole 1000V Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AF2850-30-11-70?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF2850-30-11-70 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF2850-30-11-70
Material Number
1SFL687001R7011
Manufacturer
ABB
Product ID
87895

Get a Free Quote

Request pricing and availability for AF2850-30-11-70.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
43 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 2850 A (1000 V) 55 °C 2600 A (1000 V) 70 °C 2300 A (690 V) 40 °C 2850 A (690 V) 55 °C 2600 A (690 V) 70 °C 2300 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
See all specifications

Product Highlights

  1. Current Rating: Conventional free-air thermal current 2850 A at 40 °C and AC-1 operational current 2850 A at 40 °C, derated to 2600 A at 55 °C and 2300 A at 70 °C
  2. Main Circuit: 3 NO main contacts rated 1000 V at 60 Hz with bar terminals accepting 100 mm² conductors
  3. Control Circuit: Coil voltage 100 to 250 V AC at 50/60 Hz or DC, operating limits 0.85 to 1.1 x Uc up to 70 °C
  4. Auxiliary Contacts: 1 NO and 1 NC auxiliary contact with flexible, solid, or stranded conductor capacity of 0.75 to 4 mm²
  5. Coil Consumption: Pull-in 2450 VA at 50 Hz, 2540 VA at 60 Hz, or 2290 W DC, holding 48 VA AC or 20.5 W DC
  6. Switching Times: Coil energization to NO closing 50 to 80 ms, de-energization to NO opening 35 to 55 ms
  7. Mechanical Durability: 0.3 million operating cycles with maximum mechanical switching frequency of 60 cycles per hour
  8. Insulation and Impulse Withstand: Rated insulation voltage 1000 V and rated impulse withstand voltage 8 kV
  9. Ambient and Altitude: Operating and storage temperature -40 to 70 °C with maximum operating altitude 3000 m without derating
  10. Terminal Protection: Coil terminals IP20 and main terminals IP00 according to IEC 60529
AF2850-30-11-70

Product Information

Technical Specifications

Specifications for AF2850-30-11-70

ParameterValue
Product Net Width438 mm
Product Net Depth / Length244 mm
Product Net Height422 mm
Product Net Weight43 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 2850 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 2850 A (1000 V) 55 °C 2600 A (1000 V) 70 °C 2300 A (690 V) 40 °C 2850 A (690 V) 55 °C 2600 A (690 V) 70 °C 2300 A
Maximum Electrical Switching Frequency(AC-1) 15 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability0.3 million
Maximum Mechanical Switching Frequency60 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
ParameterValue
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A Holding at Max. Rated Control Circuit Voltage DC 20.5 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2540 V·A Pull-in at Max. Rated Control Circuit Voltage DC 2290 W
Operate TimeBetween Coil De-energization and NC Contact Closing 35 ... 55 ms Between Coil De-energization and NO Contact Opening 35 ... 55 ms Between Coil Energization and NC Contact Opening 50 ... 80 ms Between Coil Energization and NO Contact Closing 50 ... 80 ms
Connecting Capacity Main CircuitBar 100 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 2850 A (600 V AC) 2850 A
Ambient Air TemperatureClose to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
Manufacturer ID1SFL687001R7011

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB AF2850-30-11-70 3-Pole 1000V Contactor with Pre-Mounted Auxiliary Contacts