- AF190-30-22-13
The ABB AF190-30-22-13 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 55 °C, 156 A at 500 V, 135 A at 690 V, and 85 A at 1000 V. Corresponding AC-3 rated operational power is 90 kW at 415 V, 110 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight 2.4 kg. Manufacturer ID 1SFL487002R1322.
- AF190-30-22-14
The ABB AF190-30-22-14 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 55 °C, 156 A at 500 V and 55 °C, 135 A at 690 V and 55 °C, and 85 A at 1000 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AF190-30-22-31
The ABB AF190-30-22-31 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 60 °C, 156 A at 500 V and 60 °C, 135 A at 690 V and 60 °C, and 85 A at 1000 V and 60 °C. Rated operational power AC-3 is 90 kW at 415 V and 132 kW at 690 V. Dimensions are 125 mm wide, 165.5 mm deep, and 196 mm high, with a net weight of 2.4 kg. Manufacturer ID: 1SFL487002R3122.
- AF190-30-22-32
The ABB AF190-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 125 mm wide, 165.5 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 60 °C, and rated operational power AC-3 is 90 kW at 415 V. Manufacturer ID: 1SFL487002R3222.
- AF190-30-22-33
The ABB AF190-30-22-33 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. Main circuit terminals are bars. The rated operational voltage of the main circuit is 1000 V, with a rated frequency of 60 Hz. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, 500 V and 1000 V, and 132 kW at 690 V. Conventional free-air thermal current Ith is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 105 mm wide, 169.5 mm deep and 196 mm high, with a net weight of 2.4 kg.
- AF190-30-22-34
ABB AF190-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 ratings include 250 A at 1000 V and 40 °C, and 275 A at 690 V and 40 °C. AC-3 ratings include 190 A at 415 V and 55 °C, with rated operational power of 90 kW at 415 V and 380/400 V. Dimensions are 105 mm wide, 169.5 mm deep, and 196 mm high; net weight is 2.4 kg. Manufacturer ID: 1SFL487002R3422.
- AF190-30-22-42
The ABB AF190-30-22-42 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 190 A at 415 V and 440 V, 156 A at 500 V, 135 A at 690 V, and 85 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. The control circuit is rated 110 to 120 V at 50 Hz and 60 Hz. Dimensions are 125 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AF190-30-22-43
The ABB AF190-30-22-43 is a 3-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL487002R4322. It has 3 normally open main contacts, 2 normally open auxiliary contacts, and 2 normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 380/400 V and 60 °C, with rated operational power AC-3 of 90 kW at 380/400 V. Dimensions are 125 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.