- AF190-30-22-34
ABB AF190-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 ratings include 250 A at 1000 V and 40 °C, and 275 A at 690 V and 40 °C. AC-3 ratings include 190 A at 415 V and 55 °C, with rated operational power of 90 kW at 415 V and 380/400 V. Dimensions are 105 mm wide, 169.5 mm deep, and 196 mm high; net weight is 2.4 kg. Manufacturer ID: 1SFL487002R3422.
- AF190-30-22-42
The ABB AF190-30-22-42 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 190 A at 415 V and 440 V, 156 A at 500 V, 135 A at 690 V, and 85 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. The control circuit is rated 110 to 120 V at 50 Hz and 60 Hz. Dimensions are 125 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AF190-30-22-43
The ABB AF190-30-22-43 is a 3-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL487002R4322. It has 3 normally open main contacts, 2 normally open auxiliary contacts, and 2 normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 380/400 V and 60 °C, with rated operational power AC-3 of 90 kW at 380/400 V. Dimensions are 125 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AF190-40-00-11
The ABB AF190-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V for the main circuit and a rated frequency of 60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high, with a net weight of 3.3 kg.
- AF190-40-00-13
ABB AF190-40-00-13 is an AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high; net weight is 3.3 kg. Short-circuit protection uses gG type fuses rated 355 A.
- AF190-40-00-14
The ABB AF190-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V, 440 V, and 380/400 V, each at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, and 110 kW at 440 V. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high, with a net weight of 3.3 kg. Short-circuit protection requires gG type fuses rated 355 A.
- AF190-40-11-11
The ABB AF190-40-11-11 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50 Hz, with a conventional free-air thermal current of 275 A according to IEC 60947-4-1 at 40 °C for open contactors. Rated operational current AC-3 is 190 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 55 kW at 220/230/240 V and 90 kW at 380/400 V and 415 V, and 110 kW at 440 V. The control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high, with a net weight of 3.3 kg.
- AF190-40-11-12
The ABB AF190-40-11-12 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one auxiliary contact NC. The main circuit is rated 1000 V and 50 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-3 is 190 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Main terminals are bars; dimensions are 140 mm width, 153 mm depth, and 196 mm height, with a net weight of 3.3 kg.