- AF190-40-11-11
The ABB AF190-40-11-11 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50 Hz, with a conventional free-air thermal current of 275 A according to IEC 60947-4-1 at 40 °C for open contactors. Rated operational current AC-3 is 190 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 55 kW at 220/230/240 V and 90 kW at 380/400 V and 415 V, and 110 kW at 440 V. The control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high, with a net weight of 3.3 kg.
- AF190-40-11-12
The ABB AF190-40-11-12 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one auxiliary contact NC. The main circuit is rated 1000 V and 50 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-3 is 190 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Main terminals are bars; dimensions are 140 mm width, 153 mm depth, and 196 mm height, with a net weight of 3.3 kg.
- AF190-40-11-13
The ABB AF190-40-11-13 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA. AC-3 rated operational power is 90 kW at 380/400 V and 415 V, and 110 kW at 440 V. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high, with a net weight of 3.3 kg. Mechanical durability is 5 million operating cycles.
- AF190-40-11-14
The ABB AF190-40-11-14 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It provides one normally open and one normally closed auxiliary contact. The main circuit is rated 1000 V, with a rated frequency of 60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 190 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. AC-3 rated operational power is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high; net weight is 3.3 kg.
- AF190-40-22-11
The ABB AF190-40-22-11 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It includes two normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 275 A at 40 °C. Rated operational current AC-3 is 190 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high; net weight is 3.3 kg.
- AF190-40-22-14
ABB AF190-40-22-14 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It includes two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 275 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V, 440 V, and 380/400 V, each at 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, and 55 kW at 220/230/240 V. Dimensions are 140 mm wide, 153 mm deep, and 196 mm high; net weight is 3.3 kg.
- AF190B-30-22-11
The ABB AF190B-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V. AC-3 ratings include 90 kW at 415 V and 380/400 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. AC-1 current ratings range from 275 A at 690 V and 40 °C to 185 A at 1000 V and 70 °C. Dimensions are 105 mm wide, 153 mm deep, and 196 mm high; net weight is 2.4 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF190B-30-22-12
The ABB AF190B-30-22-12 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 105 mm wide, 153 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V. Rated operational current AC-1 is 275 A at 690 V and 40 °C, and 250 A at 1000 V and 40 °C. Rated operational power AC-3 is 90 kW at 380/400 V and 415 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.