- AF190B-30-22-13
ABB AF190B-30-22-13 is a 3-pole AC contactor with 3 main contacts NO and 0 NC, plus 2 auxiliary contacts NO and 2 NC. It measures 105 mm wide, 153 mm deep, and 196 mm high, weighing 2.4 kg. The main circuit is rated 1000 V. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. Rated operational current AC-3 is 190 A at 415 V and 440 V, 135 A at 500 V and 690 V, and 85 A at 1000 V, at 55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF190B-30-22-14
The ABB AF190B-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 105 mm wide, 153 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated for 1000 V. Rated operational power in AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155. Manufacturer ID: 1SFL487063R1422.
- AF190B-30-22RT-11
The ABB AF190B-30-22RT-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 105 mm wide, 153 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V. Rated operational current AC-3 is 190 A at 415 V and 55 °C, and rated operational power AC-3 is 90 kW at 380/400 V and 415 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SFL487062R1122.
- AF190B-30-22RT-12
The ABB AF190B-30-22RT-12 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It carries two normally open and two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V. Rated operational current AC-1 (Ie) is 275 A at 690 V and 40 °C, and 250 A at 1000 V and 40 °C. Rated operational power AC-3 (Pe) is 90 kW at 380/400 V and 415 V, and 132 kW at 690 V. Rated control circuit voltage (Uc) is 48 to 130 V DC. Main circuit terminals are bars. Mechanical durability is 5 million operating cycles, with maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 105 mm width, 153 mm depth, and 196 mm height; net weight is 2.4 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF190B-30-22RT-13
The ABB AF190B-30-22RT-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 105 mm wide, 153 mm deep, and 196 mm high, weighing 2.4 kg. Rated operational voltage for the main circuit is 1000 V. Rated operational current AC-3 is 190 A at 415 V and 55 °C, and 85 A at 1000 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 55 kW at 220/230/240 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF190B-30-22RT-14
The ABB AF190B-30-22RT-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. Dimensions are 105 mm wide, 153 mm deep, and 196 mm high, with a net weight of 2.4 kg. The main circuit is rated 1000 V. Rated operational current AC-3 is 190 A at 380/400 V and 55 °C, and rated operational power AC-3 is 90 kW at 380/400 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF190B-40-22-11
ABB AF190B-40-22-11 is a four-pole AC contactor, manufacturer ID 1SFL487263R1122. It has four normally open main contacts and two normally open plus two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V. Rated operational current AC-1 is 275 A at 690 V and 40 °C, and 250 A at 1000 V and 40 °C. Rated operational current AC-3 is 190 A at 415 V and 55 °C. Rated operational power AC-3 is 90 kW at 415 V and 380/400 V, 110 kW at 440 V, 500 V and 1000 V, and 132 kW at 690 V. Control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. Mechanical durability is 5 million operations, with maximum mechanical switching frequency 300 cycles per hour. Dimensions are 140 mm wide, 153 mm deep and 196 mm high; net weight 3.3 kg.
- AF190B-40-22-12
ABB AF190B-40-22-12 AC contactor, manufacturer ID 1SFL487263R1222. Four main contacts NO and no main contacts NC, plus two auxiliary contacts NO and two auxiliary contacts NC. Rated operational voltage of the main circuit is 1000 V. Rated control circuit voltage is 48 to 130 V DC operation, 50 Hz / 60 Hz. Rated operational current AC-3 is 190 A at 55 °C for 220 / 230 / 240 V, 380 / 400 V, 415 V, and 440 V. Rated operational power AC-3 is 55 kW at 220 / 230 / 240 V, 90 kW at 380 / 400 V and 415 V, 110 kW at 440 V, 500 V, and 1000 V, and 132 kW at 690 V. Dimensions are 140 mm width, 153 mm depth, 196 mm height; net weight 3.3 kg. Mechanical durability is 5 million operations, with maximum mechanical switching frequency of 300 cycles per hour.