Product Model
AF190B-30-22RT-12
Material Number
1SFL487062R1222
Manufacturer
ABB
Product ID
74152

Get a Free Quote

Request pricing and availability for AF190B-30-22RT-12.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
2.4 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 250 A (1000 V) 55 °C 225 A (1000 V) 60 °C 225 A (1000 V) 70 °C 185 A (690 V) 40 °C 275 A (690 V) 55 °C 250 A (690 V) 60 °C 250 A (690 V) 70 °C 200 A
Rated Operational Power AC-3 (Pe)
(415 V) 90 kW (440 V) 110 kW (500 V) 110 kW (690 V) 132 kW (1000 V) 110 kW (380 / 400 V) 90 kW (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
Maximum Mechanical Switching Frequency
300 cycles per hour
See all specifications

Product Highlights

  1. Main Contacts: 3 NO main contacts and 0 NC main contacts
  2. Auxiliary Contacts: 2 NO and 2 NC auxiliary contacts
  3. Rated Operational Voltage: Main circuit 1000 V
  4. AC-1 Rated Current: 275 A at 690 V and 40 °C, 250 A at 690 V and 55 °C, 250 A at 690 V and 60 °C, 200 A at 690 V and 70 °C, 250 A at 1000 V and 40 °C, 225 A at 1000 V and 55 °C, 225 A at 1000 V and 60 °C, 185 A at 1000 V and 70 °C
  5. AC-3 Rated Current: 190 A at 415 V and 55 °C, 190 A at 440 V and 55 °C, 135 A at 500 V and 55 °C, 135 A at 690 V and 55 °C, 85 A at 1000 V and 55 °C
  6. AC-3 Rated Power: 90 kW at 415 V, 110 kW at 440 V, 110 kW at 500 V, 132 kW at 690 V, 110 kW at 1000 V, 90 kW at 380 / 400 V, 55 kW at 220 / 230 / 240 V
  7. UL/CSA Horsepower Rating: 50 hp at 200 ... 208 V AC three phase, 60 hp at 220 ... 240 V AC three phase, 125 hp at 440 ... 480 V AC three phase, 150 hp at 550 ... 600 V AC three phase
  8. Rated Short-time Withstand Current: 1900 A for 1 s, 1520 A for 10 s, 878 A for 30 s, 621 A for 1 min, 275 A for 15 min at 40 °C ambient in free air from a cold state
  9. Mechanical Durability: 5 million operating cycles with maximum mechanical switching frequency of 300 cycles per hour
  10. Rated Control Circuit Voltage: 48 ... 130 V DC operation, 48 ... 130 V at 50 Hz / 60 Hz
  11. Coil Consumption: 4 V·A holding at maximum rated control circuit voltage at 50 Hz or 60 Hz, 180 V·A pull-in at maximum rated control circuit voltage at 50 Hz or 60 Hz, 150 W pull-in at maximum rated control circuit voltage DC
  12. Terminal Type: Main circuit bars
  13. Dimensions: 105 mm width, 153 mm depth/length, 196 mm height
  14. Weight: 2.4 kg
  15. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373
AF190B-30-22RT-12

Product Information

Technical Specifications

Specifications for AF190B-30-22RT-12

ParameterValue
Product Net Width105 mm
Product Net Depth / Length153 mm
Product Net Height196 mm
Product Net Weight2.4 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 1000 V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 250 A (1000 V) 55 °C 225 A (1000 V) 60 °C 225 A (1000 V) 70 °C 185 A (690 V) 40 °C 275 A (690 V) 55 °C 250 A (690 V) 60 °C 250 A (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 190 A (440 V) 55 °C 190 A (500 V) 55 °C 135 A (690 V) 55 °C 135 A (1000 V) 55 °C 85 A (380400 V) 55 °C 190 A (220230240 V) 55 °C 190 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 190 A (440 V) 60 °C 190 A (500 V) 60 °C 135 A (690 V) 60 °C 135 A (1000 V) 60 °C 85 A (380400 V) 60 °C 190 A (220230240 V) 60 °C 190 A
Rated Operational Power AC-3 (Pe)(415 V) 90 kW (440 V) 110 kW (500 V) 110 kW (690 V) 132 kW (1000 V) 110 kW (380400 V) 90 kW (220230240 V) 55 kW
Rated Operational Power AC-3e (Pe)(415 V) 90 kW (440 V) 110 kW (500 V) 110 kW (690 V) 132 kW (1000 V) 110 kW (380400 V) 90 kW (220230240 V) 55 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
ParameterValue
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 250 A (100 V) 1 Pole, 60 °C 250 A (100 V) 1 Pole, 70 °C 200 A (110 V) 2 Poles in Series, 40 °C 250 A (110 V) 2 Poles in Series, 60 °C 250 A (110 V) 2 Poles in Series, 70 °C 200 A (110 V) 3 Poles in Series, 40 °C 250 A (110 V) 3 Poles in Series, 60 °C 250 A (110 V) 3 Poles in Series, 70 °C 200 A (175 V) 2 Poles in Series, 40 °C 250 A (175 V) 2 Poles in Series, 60 °C 250 A (175 V) 2 Poles in Series, 70 °C 200 A (200 V) 2 Poles in Series, 40 °C 250 A (200 V) 2 Poles in Series, 60 °C 250 A (200 V) 2 Poles in Series, 70 °C 200 A (220 V) 3 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 60 °C 250 A (220 V) 3 Poles in Series, 70 °C 200 A (260 V) 3 Poles in Series, 40 °C 250 A (260 V) 3 Poles in Series, 60 °C 250 A (260 V) 3 Poles in Series, 70 °C 200 A (300 V) 3 Poles in Series, 40 °C 250 A (300 V) 3 Poles in Series, 60 °C 250 A (300 V) 3 Poles in Series, 70 °C 200 A (72 V) 1-Pole, 40 °C 250 A (72 V) 1-Pole, 60 °C 250 A (72 V) 1-Pole, 70 °C 200 A (72 V) 2 Poles in Series, 40 °C 250 A (72 V) 2 Poles in Series, 60 °C 250 A (72 V) 2 Poles in Series, 70 °C 200 A (72 V) 3 Poles in Series, 40 °C 250 A (72 V) 3 Poles in Series, 60 °C 250 A (72 V) 3 Poles in Series, 70 °C 200 A (90 V) 1 Pole, 40 °C 250 A (90 V) 1 Pole, 60 °C 250 A (90 V) 1 Pole, 70 °C 200 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 250 A (110 V) 2 Poles in Series, 60 °C 250 A (110 V) 2 Poles in Series, 70 °C 200 A (110 V) 3 Poles in Series, 40 °C 250 A (110 V) 3 Poles in Series, 60 °C 250 A (110 V) 3 Poles in Series, 70 °C 200 A (220 V) 3 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 60 °C 250 A (220 V) 3 Poles in Series, 70 °C 200 A (72 V) 2 Poles in Series, 40 °C 250 A (72 V) 2 Poles in Series, 60 °C 250 A (72 V) 2 Poles in Series, 70 °C 200 A (72 V) 3 Poles in Series, 40 °C 250 A (72 V) 3 Poles in Series, 60 °C 250 A (72 V) 3 Poles in Series, 70 °C 200 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 250 A (110 V) 2 Poles in Series, 60 °C 250 A (110 V) 2 Poles in Series, 70 °C 200 A (110 V) 3 Poles in Series, 40 °C 250 A (110 V) 3 Poles in Series, 60 °C 250 A (110 V) 3 Poles in Series, 70 °C 200 A (220 V) 3 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 60 °C 250 A (220 V) 3 Poles in Series, 70 °C 200 A (72 V) 2 Poles in Series, 40 °C 250 A (72 V) 2 Poles in Series, 60 °C 250 A (72 V) 2 Poles in Series, 70 °C 200 A (72 V) 3 Poles in Series, 40 °C 250 A (72 V) 3 Poles in Series, 60 °C 250 A (72 V) 3 Poles in Series, 70 °C 200 A
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 48 ... 130 V DC Operation 48 ... 130 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Terminal TypeMain Circuit: Bars
General Use Rating UL/CSA(600 V AC) 250 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 50 hp (220 ... 240 V AC) Three Phase 60 hp (440 ... 480 V AC) Three Phase 125 hp (550 ... 600 V AC) Three Phase 150 hp
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SFL487062R1222