- CA504-ZG
ABB CA504-ZG is an industrial catalog item. Key specifications include Product Net Width: 86 mm, Product Net Height: 86 mm, Product Net Depth / Length: 10 mm, and Product Net Weight: 20.8 g. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- CA5X-01
ABB CA5X-01 auxiliary contact block, manufacturer ID 1SBN019010R1001. It provides one normally closed (NC) auxiliary contact and no normally open (NO) contacts. Dimensions are 10 mm wide, 47 mm deep, and 36 mm high, with a net weight of 0.014 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Screw terminals are used. Suitable for AX06 through AX150 and NX. ETIM classification EC000041 auxiliary contact block.
- CA5X-04E
The ABB CA5X-04E is an auxiliary contact block with four normally closed (NC) contacts and no normally open (NO) contacts. It uses screw terminals and is suitable for AX50, AX65, AX80, AX95, AX115, and AX150 contactors. Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high, with a net weight of 0.06 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour.
- CA5X-04M
ABB auxiliary contact block, display model CA5X-04M, manufacturer ID 1SBN019040R1104. It provides four auxiliary contacts, all normally closed (NC), with zero normally open (NO) contacts. Dimensions are 43 mm width, 32.5 mm depth, and 47 mm height; net weight is 0.06 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Terminals are screw type. Suitable for AX06, AX09, AX12, AX18, AX25, AX32, and AX40.
- CA5X-04N
ABB CA5X-04N auxiliary contact block, manufacturer ID 1SBN019040R1204. Front-mounted, four-pole device with four normally closed (NC) auxiliary contacts and no normally open (NO) contacts. Screw terminals. Suitable for NX. Rated operational voltage: auxiliary circuit 690 V, main circuit 690 V. Conventional free-air thermal current (Ith) 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage (Ui) 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Rated operational current AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, 2 A at 690 V. Rated short-time withstand current: 140 A for 0.1 s, 100 A for 1 s. Maximum electrical switching frequency 1200 cycles per hour (AC-15), 900 cycles per hour (DC-13); mechanical 3600 cycles per hour. Dimensions: 43 mm width, 32.5 mm depth, 47 mm height; net weight 0.06 kg.
- CA5X-04U
The ABB CA5X-04U is a front-mounted auxiliary contact block with four normally closed (NC) auxiliary contacts and no normally open (NO) contacts. It uses screw terminals and is suitable for AX06, AX09, AX12, AX18, AX25, AX32, and AX40. Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.06 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour.
- CA5X-10
The ABB CA5X-10 is a front-mounted auxiliary contact block with one normally open (N.O.) instantaneous contact and no normally closed contacts. It uses screw terminals and is suitable for AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80, AX95, AX115, AX150 contactors and NX contactor relays. Dimensions are 10 mm wide, 47 mm deep, and 36 mm high, with a net weight of 0.014 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 degrees C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 690 V.
- CA5X-13M
ABB auxiliary contact block, model CA5X-13M. Manufacturer ID 1SBN019040R1113. It provides 1 normally open and 3 normally closed auxiliary contacts in a front-mounted unit with screw terminals, suitable for AX06, AX09, AX12, AX18, AX25, AX32 and AX40. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour. Dimensions are 43 mm wide, 32.5 mm deep and 47 mm high; net weight 0.06 kg.