- CA5X-13M
ABB auxiliary contact block, model CA5X-13M. Manufacturer ID 1SBN019040R1113. It provides 1 normally open and 3 normally closed auxiliary contacts in a front-mounted unit with screw terminals, suitable for AX06, AX09, AX12, AX18, AX25, AX32 and AX40. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour. Dimensions are 43 mm wide, 32.5 mm deep and 47 mm high; net weight 0.06 kg.
- CA5X-13N
The ABB CA5X-13N is a front-mounted auxiliary contact block with screw terminals, suitable for NX. It has 1 normally open (NO) and 3 normally closed (NC) auxiliary contacts. Dimensions are 43 mm width, 32.5 mm depth, and 47 mm height, with a net weight of 0.06 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current (Ith) is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 690 V. Rated insulation voltage (Ui) is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour.
- CA5X-22E
ABB CA5X-22E auxiliary contact block, manufacturer ID 1SBN019040R1022, with 2 NO and 2 NC auxiliary contacts and screw terminals. It is suitable for AX50, AX65, AX80, AX95, AX115, and AX150. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour; maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13). Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.06 kg.
- CA5X-22M
ABB CA5X-22M auxiliary contact block with screw terminals, 2 NO and 2 NC auxiliary contacts. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 2 A at 690 V, 6 A at 24/127 V, 4 A at 220/240 V, and 3 A at 380/400 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum electrical switching frequency is 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13; maximum mechanical switching frequency is 3600 cycles per hour. Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.06 kg. Suitable for AX06, AX09, AX12, AX18, AX25, AX32, and AX40.
- CA5X-22N
The ABB CA5X-22N is a front-mounted auxiliary contact block with two normally open and two normally closed contacts, fitted with screw terminals. It is suitable for NX applications. Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high, with a net weight of 0.06 kg. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Maximum mechanical switching frequency is 3600 cycles per hour; maximum electrical switching frequency is 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13).
- CA5X-22U
The ABB CA5X-22U is a front-mounted auxiliary contact block with four poles, comprising two normally open (NO) and two normally closed (NC) auxiliary contacts. It uses screw terminals and is suitable for AX06, AX09, AX12, AX18, AX25, AX32, and AX40 devices. The rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current (Ith) is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage (Ui) is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.06 kg. Maximum mechanical switching frequency is 3600 cycles per hour.
- CA5X-31E
ABB CA5X-31E auxiliary contact block with 3 normally open and 1 normally closed auxiliary contacts and screw terminals. It is suitable for AX50, AX65, AX80, AX95, AX115, and AX150. Rated operational voltage is 690 V for the auxiliary circuit and 690 V for the main circuit. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 2 A at 690 V, 6 A at 24/127 V, 4 A at 220/240 V, and 3 A at 380/400 V. Maximum electrical switching frequency is 1200 cycles per hour for AC-15 and 900 cycles per hour for DC-13. Dimensions are 43 mm wide, 32.5 mm deep, and 47 mm high; net weight is 0.06 kg.
- CA5X-31M
ABB CA5X-31M auxiliary contact block with manufacturer ID 1SBN019040R1131. It provides 3 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with screw terminals. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and VDE 0110 (Gr. C). Dimensions are 43 mm width, 32.5 mm depth, 47 mm height, and 0.06 kg net weight. Suitable for AX06, AX09, AX12, AX18, AX25, AX32, and AX40. Maximum mechanical switching frequency is 3600 cycles per hour.