- CM-TCS.11S
ABB CM-TCS.11S intermediate relay, manufacturer ID 1SVR730740R0100, monitors temperature with PT100 sensors over a measuring range of -50 to +50 °C. Functions include overtemperature monitoring, undertemperature monitoring, and over- and undertemperature monitoring. Rated control supply voltage is 24 to 240 V AC/DC, with supply circuit 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.151 kg. Housing protection is IP50, terminals IP20, overvoltage category III.
- CM-TCS.12P
The ABB CM-TCS.12P is an intermediate relay for temperature monitoring, identified by manufacturer ID 1SVR740740R0200. It supports overtemperature, undertemperature, and over/undertemperature monitoring with a measuring range of 0 to +100 °C using PT100 sensors. The rated control supply voltage is 24 to 240 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts. Rated operational currents include 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighing 0.14 kg. Housing protection is IP50, terminals IP20, overvoltage category III.
- CM-TCS.12S
The ABB CM-TCS.12S is an intermediate relay for temperature monitoring, identified by manufacturer ID 1SVR730740R0200. It accepts PT100 sensors and monitors overtemperature, undertemperature, and over- and undertemperature conditions across a measuring range of 0 to +100 °C. The rated control supply voltage is 24 to 240 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, and DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts via screw terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; weight is 0.151 kg.
- CM-TCS.13P
The ABB CM-TCS.13P is an intermediate relay for overtemperature, undertemperature, and combined over/undertemperature monitoring. It accepts PT100 sensors and covers a measuring range of 0 to +200 °C. The rated control supply voltage is 24 to 240 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.14 kg. Housing protection is IP50, terminals IP20, overvoltage category III.
- CM-TCS.13S
The ABB CM-TCS.13S is an intermediate relay for temperature monitoring, identified by manufacturer ID 1SVR730740R0300. It supports overtemperature, undertemperature, and combined over/undertemperature monitoring with PT100 sensors over a measuring range of 0 to +200 °C. Rated control supply voltage is 24 to 240 V AC/DC, with supply circuit rated frequency of 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts via screw terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.151 kg. Housing protection is IP50, terminals IP20, overvoltage category III.
- CM-TCS.21P
The ABB CM-TCS.21P is an intermediate relay for temperature monitoring with a PT100 sensor input. Its measuring range is -50 to +50 °C, and it supports overtemperature monitoring, undertemperature monitoring, and combined over- and undertemperature monitoring. The rated control supply voltage is 24 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts. Terminals are screwless. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.127 kg. Housing protection is IP50 and terminal protection is IP20. Rated operational currents include 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13.
- CM-TCS.21S
The ABB CM-TCS.21S is an intermediate relay for temperature monitoring, with manufacturer ID 1SVR730740R9100. It provides overtemperature, undertemperature, and over/undertemperature monitoring across a measuring range of -50 to +50 °C using a PT100 sensor. The rated control supply voltage is 24 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.138 kg, and uses screw terminals.
- CM-TCS.22P
The ABB CM-TCS.22P is an intermediate relay for temperature monitoring, identified by manufacturer ID 1SVR740740R9200. It supports overtemperature, undertemperature, and over/undertemperature monitoring with a PT100 sensor over a measuring range of 0 to +100 °C. The rated control supply voltage is 24 V AC/DC, with supply circuit frequencies of 50 Hz, 60 Hz, or DC. Output is configurable as 2 x 1 c/o or 1 x 2 c/o contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. The minimum switching capacity is 24 V, 10 mA. Terminals are screwless. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; weight is 0.127 kg. Housing protection is IP50, terminals IP20.