Industrial Automation Parts. Prompt replies from real people.

ABB CM-TCS.12S Temperature Monitoring Relay

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ABB CM-TCS.12S?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB CM-TCS.12S cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
CM-TCS.12S
Material Number
1SVR730740R0200
Manufacturer
ABB
Product ID
85261

Get a Free Quote

Request pricing and availability for CM-TCS.12S.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.151 kg
Rated Control Supply Voltage (Us)
24 ... 240 V AC/DC
Rated Frequency (f)
Supply Circuit 50 Hz Supply Circuit 60 Hz Supply Circuit DC
Rated Operational Current AC-12 (Ie)
(230 V) 4 A
Rated Impulse Withstand Voltage (Uimp)
Measuring Circuit / Output Circuit 4 kV Output Circuit 1 / Output Circuit 2 4 kV Supply Circuit / Measuring Circuit 4 kV Supply Circuit / Output Circuit 4 kV
Degree of Protection
Housing IP50 Terminals IP20
See all specifications

Product Highlights

  1. Temperature Monitoring Functions: Supports overtemperature monitoring, undertemperature monitoring, and over- and undertemperature monitoring
  2. Measuring Range and Sensor: 0 to +100 °C measuring range with PT100 sensor input
  3. Configurable Output Contacts: 2 x 1 c/o or 1 x 2 c/o contacts, configurable
  4. Supply Voltage: 24 to 240 V AC/DC rated control supply voltage
  5. Ambient Temperature Range: Operation -40 to +60 °C, storage -40 to +85 °C
CM-TCS.12S

Product Information

Technical Specifications

Specifications for CM-TCS.12S

ParameterValue
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.151 kg
FunctionOvertemperature monitoring Undertemperature monitoring Over- and undertemperature monitoring
Measuring Range0 ... +100 °C
Sensor TypePT100
Rated Control Supply Voltage (Us)24 ... 240 V AC/DC
Rated Frequency (f)Supply Circuit 50 Hz Supply Circuit 60 Hz Supply Circuit DC
Output2 x 1 c/o or 1 x 2 c/o contacts, configurable
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V 10 mA
Rated Impulse Withstand Voltage (Uimp)Measuring CircuitOutput Circuit 4 kV Output Circuit 1Output Circuit 2 4 kV Supply CircuitMeasuring Circuit 4 kV Supply CircuitOutput Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring CircuitOutput Circuit 300 V Output Circuit 1Output Circuit 2 300 V Supply CircuitMeasuring Circuit 300 V Supply CircuitOutput Circuit 300 V
Degree of ProtectionHousing IP50 Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
ParameterValue
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical Durability30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm² Flexible with Ferrule 2x 0.5 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² Flexible 1x 0.5 ... 2.5 mm² Flexible 2x 0.5 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4 4.5 Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.60947-5-1 IEC/EN 60255-26 IEC/EN 60255-27 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 63000 UL 60947-5-1 IEC/EN 60947-5-1
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG Flexible 2x 18-16 AWG Rigid 1x 20-12 AWG Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Ambient Air TemperatureOperation -40 ... +60 °C Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Object Classification CodeB
ETIM 7EC001446 - Temperature monitoring relay
ETIM 8EC001446 - Temperature monitoring relay
ETIM 9EC001446 - Temperature monitoring relay
eClassV11.0 : 27371810
UNSPSC39122331
E-Number (Finland)2712324
E-Number (Norway)4187809
E-Number (Sweden)3860664
Manufacturer ID1SVR730740R0200

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp