- AF116-30-00-13
The ABB AF116-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 380/400 V and 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-00-14
The ABB AF116-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 690 V and 60 °C, and 130 A at 690 V and 70 °C. AC-3 ratings include 116 A at 415 V and 55 °C, and 65 A at 690 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 55 kW at 690 V.
- AF116-30-00-31
The ABB AF116-30-00-31 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF116-30-00-32
The ABB AF116-30-00-32 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF116-30-00-33
The ABB AF116-30-00-33 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL427001R3300.
- AF116-30-00-34
The ABB AF116-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 440 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, and 30 kW at 220/230/240 V. The manufacturer ID is 1SFL427001R3400.
- AF116-30-00-42
The ABB AF116-30-00-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 380/400 V, 415 V, 440 V, 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 400 V, 415 V, 500 V, and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.55 kg. Manufacturer ID: 1SFL427001R4200.
- AF116-30-00-43
The ABB AF116-30-00-43 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Manufacturer ID: 1SFL427001R4300.