- AF116-30-00B-11
The ABB AF116-30-00B-11 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 160 A according to IEC 60947-4-1 at 40 °C. AC-3 ratings include 116 A at 415 V and 55 °C, and 65 A at 690 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 690 V, and 30 kW at 220/230/240 V. The coil accepts 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg. Manufacturer ID 1SFL427002R1100.
- AF116-30-00B-12
The ABB AF116-30-00B-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its manufacturer ID is 1SFL427002R1200. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF116-30-00B-13
The ABB AF116-30-00B-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, and 380/400 V at 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, and 55 kW at 690 V. Manufacturer ID: 1SFL427002R1300.
- AF116-30-00B-14
The ABB AF116-30-00B-14 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 380/400 V, 415 V, 440 V, 220/230/240 V, and 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 380/400 V and 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-00B-31
The ABB AF116-30-00B-31 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Manufacturer ID: 1SFL427002R3100.
- AF116-30-00B-32
The ABB AF116-30-00B-32 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.3 kg. Manufacturer ID: 1SFL427002R3200.
- AF116-30-00B-33
The ABB AF116-30-00B-33 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V and 380/400 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF116-30-00B-34
The ABB AF116-30-00B-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, and 55 kW at 690 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.3 kg. Manufacturer ID: 1SFL427002R3400.