- AF116-30-00B-42
The ABB AF116-30-00B-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Rated making capacity AC-3 is 10 x Ie; rated breaking capacity AC-3 is 8 x Ie. Manufacturer ID: 1SFL427002R4200.
- AF116-30-00B-43
The ABB AF116-30-00B-43 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Manufacturer ID: 1SFL427002R4300.
- AF116-30-11-11
The ABB AF116-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V in the main circuit at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 440 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, and 55 kW at 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF116-30-11-12
The ABB AF116-30-11-12 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, and 55 kW at 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL427001R1211.
- AF116-30-11-13
The ABB AF116-30-11-13 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V and 500 V. Manufacturer ID: 1SFL427001R1311.
- AF116-30-11-14
The ABB AF116-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V in the main circuit at 50/60 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 116 A at 415 V and 55 °C, and rated operational power of 55 kW at 415 V and 75 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Manufacturer ID: 1SFL427001R1411.
- AF116-30-11-31
The ABB AF116-30-11-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. The manufacturer ID is 1SFL427001R3111.
- AF116-30-11-32
ABB AF116-30-11-32 AC contactor, manufacturer ID 1SFL427001R3211. It has three normally open main contacts, no normally closed main contacts, and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 90 mm wide, 138.5 mm deep, 150 mm high; net weight 1.55 kg.