Product Model
AF116-30-00B-43
Material Number
1SFL427002R4300
Manufacturer
ABB
Product ID
85341

Get a Free Quote

Request pricing and availability for AF116-30-00B-43.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.3 kg
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A (690 V) 60 °C 145 A (690 V) 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(400 V) 55 kW (415 V) 55 kW (440 V) 75 kW (500 V) 55 kW (380 / 400 V) 55 kW (220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
See all specifications

Product Highlights

  1. Main Contacts: 3 normally open (NO) main contacts, no normally closed or auxiliary contacts
  2. Power Ratings: AC-3 rated 55 kW at 380 to 415 V and 500 V, 75 kW at 440 V, and 30 kW at 220 to 240 V, UL/CSA three-phase ratings of 30 hp at 200 to 208 V, 40 hp at 220 to 240 V, 75 hp at 440 to 480 V, and 100 hp at 550 to 600 V
  3. Current Ratings: AC-1 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C, AC-3 116 A at 220 to 440 V and 65 A at 690 V
  4. Coil and Control: Rated control circuit voltage 220 to 240 V at 50 or 60 Hz, with pull-in consumption of 130 V·A and holding consumption of 8 V·A / 2.5 W
  5. Durability and Switching: Mechanical durability of 5 million cycles, maximum mechanical switching frequency of 300 cycles per hour, and operate times of 15 to 20 ms for NO contact opening and 20 to 35 ms for NO contact closing
  6. Terminations and Protection: Main circuit bar terminals accept rigid Cu cable 1 x 10 to 95 mm² or flexible cable 2 x 10 to 70 mm², main terminals are IP00 and coil terminals are IP20
  7. Operating Conditions: Rated operational voltage 690 V AC at 50/60 Hz, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and maximum operating altitude 3000 m without derating
  8. Dimensions and Mounting: 150 mm H x 90 mm W x 126 mm D, net weight 1.3 kg
AF116-30-00B-43

Product Information

Technical Specifications

Specifications for AF116-30-00B-43

ParameterValue
Product Net Width90 mm
Product Net Depth / Length126 mm
Product Net Height150 mm
Product Net Weight1.3 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 160 A (690 V) 60 °C 145 A (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 116 A (440 V) 60 °C 116 A (500 V) 60 °C 110 A (690 V) 60 °C 65 A (380400 V) 60 °C 116 A (220230240 V) 60 °C 116 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 116 A (440 V) 60 °C 116 A (500 V) 60 °C 110 A (690 V) 60 °C 65 A (380400 V) 60 °C 116 A (220230240 V) 60 °C 116 A
Rated Operational Power AC-3 (Pe)(400 V) 55 kW (415 V) 55 kW (440 V) 75 kW (500 V) 55 kW (380400 V) 55 kW (220230240 V) 30 kW
Rated Operational Power AC-3e (Pe)(415 V) 55 kW (440 V) 75 kW (500 V) 75 kW (690 V) 55 kW (380400 V) 55 kW (220230240 V) 30 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
ParameterValue
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 240 V 60 Hz 220 ... 240 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 8 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 2.5 W Holding at Max. Rated Control Circuit Voltage 60 Hz 8 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 2.5 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Operate TimeBetween Coil De-energization and NO Contact Opening 15 ... 20 ms Between Coil Energization and NO Contact Closing 20 ... 35 ms
Connecting Capacity Main CircuitFlexible 2 x 10 ... 70 mm² Rigid Cu-Cable 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 1x 0.75 ... 2.5 mm² Flexible 2x 0.75 ... 2.5 mm² Solid 1x 1 ... 4 mm² Solid 2x 1 ... 4 mm² Stranded 1x 1 ... 4 mm² Stranded 2x 1 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm Control Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 160 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 30 hp (220 ... 240 V AC) Three Phase 40 hp (440 ... 480 V AC) Three Phase 75 hp (550 ... 600 V AC) Three Phase 100 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 71 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
Manufacturer ID1SFL427002R4300

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.