- AF116-30-11-42
The ABB AF116-30-11-42 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Manufacturer ID: 1SFL427001R4211.
- AF116-30-11-43
The ABB AF116-30-11-43 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Manufacturer ID: 1SFL427001R4311.
- AF116-30-11B-11
The ABB AF116-30-11B-11 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-11B-12
The ABB AF116-30-11B-12 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, and 380/400 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-11B-13
The ABB AF116-30-11B-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz, with AC-1 rated operational current of 160 A at 40 °C and AC-3 ratings of 116 A at 415 V and 55 °C, and 65 A at 690 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 30 kW at 220/230/240 V. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg. Mechanical durability is 5 million operations. Main terminals are bars; coil terminals are IP20 and main terminals IP00 per IEC 60529.
- AF116-30-11B-14
The ABB AF116-30-11B-14 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V and 500 V. Manufacturer ID: 1SFL427002R1411.
- AF116-30-11B-31
The ABB AF116-30-11B-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 30 kW at 220/230/240 V. Manufacturer ID: 1SFL427002R3111.
- AF116-30-11B-32
The ABB AF116-30-11B-32 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, and rated operational power AC-3 is 55 kW at 400 V. Rated making capacity AC-3 is 10 x Ie AC-3; rated breaking capacity AC-3 is 8 x Ie AC-3.