- AF116-30-11B-31
The ABB AF116-30-11B-31 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 30 kW at 220/230/240 V. Manufacturer ID: 1SFL427002R3111.
- AF116-30-11B-32
The ABB AF116-30-11B-32 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, and rated operational power AC-3 is 55 kW at 400 V. Rated making capacity AC-3 is 10 x Ie AC-3; rated breaking capacity AC-3 is 8 x Ie AC-3.
- AF116-30-11B-33
ABB AF116-30-11B-33 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. AC-3 ratings include 116 A at 415 V and 55 °C, and 65 A at 690 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 55 kW at 690 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; weight is 1.3 kg.
- AF116-30-11B-34
The ABB AF116-30-11B-34 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V at 50 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high, with a net weight of 1.3 kg. Manufacturer ID: 1SFL427002R3411.
- AF116-30-11B-42
The ABB AF116-30-11B-42 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Manufacturer ID: 1SFL427002R4211.
- AF116-30-11B-43
The ABB AF116-30-11B-43 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 116 A at 415 V and 65 A at 690 V, and AC-3 power ratings of 55 kW at 400 V and 75 kW at 440 V. The control circuit is rated 220 to 240 V at 50 Hz and 60 Hz. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, weighing 1.3 kg. Mechanical durability is 5 million operations. The main terminals are bars; coil terminals are IP20 and main terminals IP00. Maximum operating altitude without derating is 3000 m.
- AF116-30-22-11
ABB AF116-30-22-11 AC contactor, manufacturer ID 1SFL427001R1122. Three-pole non-reversing contactor with 3 NO main contacts, 2 NO and 2 NC auxiliary contacts, and a double-clamp terminal type. Main circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 116 A at 415 V and 55 °C, 110 A at 500 V, and 65 A at 690 V; corresponding AC-3 rated operational power is 55 kW at 415 V and 30 kW at 220/230/240 V. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.55 kg. Mechanical durability is 5 million operating cycles.
- AF116-30-22-12
The ABB AF116-30-22-12 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 116 A at 415 V and 55 °C, and rated operational power is 55 kW at 415 V. Coil control voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Mechanical durability is 5 million operating cycles. Maximum operating altitude without derating is 3000 m.