- NF62E-11 24-60V50/60HZ 20-60VDC
ABB NF62E-11 24-60V50/60HZ 20-60VDC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 24...60V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF62E-12
The ABB NF62E-12 is an intermediate relay with six normally open and two normally closed auxiliary contacts. Its control circuit operates at 48 to 130 V DC and 48 to 130 V at 50 or 60 Hz. The auxiliary circuit is rated 690 V, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Maximum mechanical switching frequency is 6000 cycles per hour; maximum electrical switching frequency is 1200 cycles per hour at AC-15 and 900 cycles per hour at DC-13. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high, weighing 0.32 kg. Screw terminals accept 0.75 to 2.5 mm² conductors. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF62E-12 48-130V50/60HZ-DC
ABB NF62E-12 48-130V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 48...130V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF62E-13
The ABB NF62E-13 is an intermediate relay with 6 NO and 2 NC auxiliary contacts. Its control circuit accepts 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; net weight 0.32 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on two diagonal M4 screws. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF62E-13 100-250V50/60HZ-DC
ABB NF62E-13 100-250V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 100...250V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF62E-14
ABB NF62E-14 intermediate relay, manufacturer ID 1SBH137001R1462. It has 6 normally open and 2 normally closed auxiliary contacts. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high; weight 0.36 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF62E-14 250-500V50/60HZ-DC
ABB NF62E-14 250-500V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 250...500V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF62EK-11
The ABB NF62EK-11 is an intermediate relay with six normally open and two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.33 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.