- NF62E-14 250-500V50/60HZ-DC
ABB NF62E-14 250-500V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 8-pole, Contacts configuration: NC x2 + NO x6, and Control voltage1: 250...500V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF62EK-11
The ABB NF62EK-11 is an intermediate relay with six normally open and two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.33 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.
- NF62EK-12
ABB NF62EK-12 intermediate relay, manufacturer ID 1SBH137005R1262. It has 6 NO and 2 NC auxiliary contacts, push-in spring terminals, and a rated operational voltage of 690 V for both auxiliary and main circuits. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.33 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF62EK-13
ABB NF62EK-13 intermediate relay, manufacturer ID 1SBH137005R1362. It has 6 NO and 2 NC auxiliary contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, with rated frequency 50/60 Hz for auxiliary and control circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high; net weight 0.33 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF62EK-14
ABB NF62EK-14 intermediate relay, manufacturer ID 1SBH137005R1462. Auxiliary contacts: 6 NO and 2 NC. Rated operational voltage is 690 V for both auxiliary and main circuits. Rated frequency is 50/60 Hz for auxiliary and control circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Rated control circuit voltage is 250 to 500 V at 50 Hz, 250 to 500 V at 60 Hz, and 250 to 500 V DC. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high; weight 0.37 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF631-3MB6A
ABB NF631-3MB6A is an industrial catalog item. Key specifications include Brand / Label: NO, EPLAN Product Categorization: Main Product WITH Accessories, Global Commercial Alias: NF631-3MB6A, and Product Net Height: 7 in. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF632-3PBJA11
ABB NF632-3PBJA11 is an industrial catalog item. Key specifications include Brand / Label: NO, EPLAN Product Categorization: Main Product WITH Accessories, Global Commercial Alias: NF632-3PBJA11, and Product Net Height: 9.25 in. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF71E-11
ABB NF71E-11 intermediate relay, manufacturer ID 1SBH137001R1171. It has 7 normally open and 1 normally closed auxiliary contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V for DC operation. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high, 0.32 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13. DIN-rail mounting per IEC 60715.