- OT800U03-1000
ABB OT800U03-1000 is a 3-pole, front-operated non-fused isolating switch for base mounting. The main circuit is rated 1000 V, with a rated impulse withstand voltage (Uimp) of 12 kV and a rated short-time withstand current (Icw) of 50 kA for 1 s. Ampere rating is 600 A. Power loss is 48 W per pole at rated operating conditions. Maximum operating voltage per UL/CSA is 1000 V. The switch is built to UL 98 and CSA C22.2 NO.4. Dimensions are 334.5 mm wide, 372 mm high, and 151.5 mm deep; net weight is 17.2 kg. A lug terminal and terminal bolt kit are included. Handle and shaft are not included.
- OT800U03C
ABB OT800U03C isolating switch, 3-pole, front-operated, base mounting. Rated operational voltage 1000 V; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 1600 A at 40 °C. Rated operational currents: AC-21A, AC-22A and AC-23A 1600 A at 380–415 V, 500 V and 690 V; AC-31B 1600 A at 380–415 V; AC-33B 1000 A at 380–415 V. Ampere rating 800 A. Rated short-time withstand current 50 kA rms for 1 s. UL/CSA horsepower ratings: 250 Hp at 240 V, 500 Hp at 480 V, 500 Hp at 600 V. Screw terminals, tightening torque 50 to 75 N·m per IEC 60947-1. Front IP20, pollution degree 3, mechanical durability 3000 cycles, 48 W power loss per pole at rated conditions. Standards: UL 98 / IEC 60947-6-1. Handle and shaft not included. Net dimensions 400 x 376 x 335 mm; 38.11 kg.
- OT800U03CP
ABB OT800U03CP is a 3-pole, front-operated isolating switch for base mounting, supplied with handle and shaft. The handle is black. The front degree of protection is IP20, and the pollution degree is 3. Conventional free-air thermal current (Ith) is 1600 A at 40 °C. Rated impulse withstand voltage (Uimp) is 12 kV. Power loss is 48 W per pole at rated operating conditions. Mechanical durability is 3000 cycles. Line terminals can be configured top in - bottom out or bottom in - top out. Net dimensions are 400 mm width, 376 mm height, and 335 mm depth; net weight is 36 kg. Manufacturer ID: 1SCA104031R1001.
- OT800U03P
ABB OT800U03P is a 3-pole, front-operated isolating switch with base mounting. The manufacturer identifier is 1SCA105665R1001. It is rated for a conventional thermal current (Ithe) of 800 A fully enclosed. The switch has a front degree of protection of IP00 and pollution degree 3. Dimensions are 334.5 mm wide, 372 mm high, and 151.5 mm deep, with a net weight of 15.7 kg. A black handle and shaft are included, and the switch is lockable. Mechanical durability is 6000 operations. Power loss at rated operating conditions is 29 W per pole. Line terminals can be configured top in, bottom out or bottom in, top out.
- OT800U04
The ABB OT800U04 is a front-operated, non-fusible isolating switch with four poles and base mounting. Its conventional thermal current (Ithe) is 800 A fully enclosed. The fourth pole is switched with a simultaneous function and is positioned on the right side. Line terminals can be configured top in - bottom out or bottom in - top out. The switch has a front degree of protection of IP00 and pollution degree 3. Mechanical durability is 6000 operations. Dimensions are 414.5 mm wide, 372 mm high, and 151.5 mm deep, with a net weight of 22.2 kg. A handle and shaft are not included. Manufacturer ID: 1SCA105636R1001.
- OT800U04-1000
ABB OT800U04-1000 isolating switch, manufacturer ID 1SCA161435R1001. Four-pole, front-operated, non-fusible design. Rated operational voltage of the main circuit is 1000 V; maximum operating voltage per UL/CSA is 1000 V. Ampere rating is 600 A. Rated impulse withstand voltage (Uimp) is 12 kV. Rated short-time withstand current (Icw) is 50 kA for 1 s. Power loss is 48 W per pole at rated operating conditions. Standards: UL 98 and CSA C22.2 NO.4. Dimensions are 414.5 mm wide, 372 mm high, and 151.5 mm deep; net weight is 22.2 kg. WEEE category 5.
- OT800U04C
ABB OT800U04C is a four-pole front-operated isolating switch for base mounting, with line terminals usable top-in/bottom-out or bottom-in/top-out. It is rated 800 A, 1000 V, with a 12 kV impulse withstand voltage and 50 kA rms short-time withstand current for 1 s. Utilization categories AC-21A, AC-22A and AC-23A are rated 1600 A at 380–415 V, 500 V and 690 V; AC-31B is 1600 A at 380–415 V and AC-33B is 1000 A at 380–415 V. UL/CSA horsepower ratings are 250 Hp at 240 V and 500 Hp at 480 V and 600 V. It has screw terminals, 50–75 N·m tightening torque per IEC 60947-1, front IP20 protection, pollution degree 3, 3000-cycle mechanical durability, and dimensions 480 x 376 x 335 mm at 47.7 kg. Standards: UL 98 and IEC 60947-6-1. Handle and shaft are not included.
- OT800U04CP
ABB OT800U04CP is a front-operated, non-fusible isolating switch with four poles. It is rated 800 A and 1000 V in the main circuit, with rated insulation voltage (Ui) 1000 V and rated impulse withstand voltage (Uimp) 12 kV. Conventional free-air thermal current (Ith) is 1600 A at 40 °C. Rated operational currents are 1600 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A; AC-31B is 1600 A at 380–415 V, and AC-33B is 1000 A at 380–415 V. Rated short-time withstand current (Icw) is 50 kA rms for 1 s. The fourth pole is switched, simultaneous, right side. Front protection is IP20; pollution degree 3. Standards: UL 98 / IEC60947-6-1. Screw terminals; tightening torque 50–75 N·m per IEC 60947-1. Mechanical durability 3000 cycles.