- OT800U03CP
ABB OT800U03CP is a 3-pole, front-operated isolating switch for base mounting, supplied with handle and shaft. The handle is black. The front degree of protection is IP20, and the pollution degree is 3. Conventional free-air thermal current (Ith) is 1600 A at 40 °C. Rated impulse withstand voltage (Uimp) is 12 kV. Power loss is 48 W per pole at rated operating conditions. Mechanical durability is 3000 cycles. Line terminals can be configured top in - bottom out or bottom in - top out. Net dimensions are 400 mm width, 376 mm height, and 335 mm depth; net weight is 36 kg. Manufacturer ID: 1SCA104031R1001.
- OT800U03P
ABB OT800U03P is a 3-pole, front-operated isolating switch with base mounting. The manufacturer identifier is 1SCA105665R1001. It is rated for a conventional thermal current (Ithe) of 800 A fully enclosed. The switch has a front degree of protection of IP00 and pollution degree 3. Dimensions are 334.5 mm wide, 372 mm high, and 151.5 mm deep, with a net weight of 15.7 kg. A black handle and shaft are included, and the switch is lockable. Mechanical durability is 6000 operations. Power loss at rated operating conditions is 29 W per pole. Line terminals can be configured top in, bottom out or bottom in, top out.
- OT800U04
The ABB OT800U04 is a front-operated, non-fusible isolating switch with four poles and base mounting. Its conventional thermal current (Ithe) is 800 A fully enclosed. The fourth pole is switched with a simultaneous function and is positioned on the right side. Line terminals can be configured top in - bottom out or bottom in - top out. The switch has a front degree of protection of IP00 and pollution degree 3. Mechanical durability is 6000 operations. Dimensions are 414.5 mm wide, 372 mm high, and 151.5 mm deep, with a net weight of 22.2 kg. A handle and shaft are not included. Manufacturer ID: 1SCA105636R1001.
- OT800U04-1000
ABB OT800U04-1000 isolating switch, manufacturer ID 1SCA161435R1001. Four-pole, front-operated, non-fusible design. Rated operational voltage of the main circuit is 1000 V; maximum operating voltage per UL/CSA is 1000 V. Ampere rating is 600 A. Rated impulse withstand voltage (Uimp) is 12 kV. Rated short-time withstand current (Icw) is 50 kA for 1 s. Power loss is 48 W per pole at rated operating conditions. Standards: UL 98 and CSA C22.2 NO.4. Dimensions are 414.5 mm wide, 372 mm high, and 151.5 mm deep; net weight is 22.2 kg. WEEE category 5.
- OT800U04C
ABB OT800U04C is a four-pole front-operated isolating switch for base mounting, with line terminals usable top-in/bottom-out or bottom-in/top-out. It is rated 800 A, 1000 V, with a 12 kV impulse withstand voltage and 50 kA rms short-time withstand current for 1 s. Utilization categories AC-21A, AC-22A and AC-23A are rated 1600 A at 380–415 V, 500 V and 690 V; AC-31B is 1600 A at 380–415 V and AC-33B is 1000 A at 380–415 V. UL/CSA horsepower ratings are 250 Hp at 240 V and 500 Hp at 480 V and 600 V. It has screw terminals, 50–75 N·m tightening torque per IEC 60947-1, front IP20 protection, pollution degree 3, 3000-cycle mechanical durability, and dimensions 480 x 376 x 335 mm at 47.7 kg. Standards: UL 98 and IEC 60947-6-1. Handle and shaft are not included.
- OT800U04CP
ABB OT800U04CP is a front-operated, non-fusible isolating switch with four poles. It is rated 800 A and 1000 V in the main circuit, with rated insulation voltage (Ui) 1000 V and rated impulse withstand voltage (Uimp) 12 kV. Conventional free-air thermal current (Ith) is 1600 A at 40 °C. Rated operational currents are 1600 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A; AC-31B is 1600 A at 380–415 V, and AC-33B is 1000 A at 380–415 V. Rated short-time withstand current (Icw) is 50 kA rms for 1 s. The fourth pole is switched, simultaneous, right side. Front protection is IP20; pollution degree 3. Standards: UL 98 / IEC60947-6-1. Screw terminals; tightening torque 50–75 N·m per IEC 60947-1. Mechanical durability 3000 cycles.
- OT800U04P
The ABB OT800U04P is a front-operated, non-fusible isolating switch with four poles and a switched fourth pole on the right side providing simultaneous function. It is rated 800 A conventional thermal current (fully enclosed), 1000 V rated operational voltage, 1000 V rated insulation voltage according to IEC/EN 60664-1, and 12 kV rated impulse withstand voltage. Rated operational current is 1600 A at AC-22A and 1250 A at AC-23A for 380 to 415 V, 500 V, and 690 V. Rated operational power at AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. It has front IP00 protection, lug terminals, base mounting, and dimensions of 414.5 mm width, 372 mm height, and 151.5 mm depth, weighing 22.5 kg. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4.
- OT800U12
The ABB OT800U12 is a 3-pole, front-operated, non-fusible isolating switch with a conventional thermal current (Ithe) of 800 A fully enclosed. It is base mounting with line terminals configurable as top in/bottom out or bottom in/top out. Rated impulse withstand voltage (Uimp) is 12 kV, pollution degree 3, and power loss is 29 W per pole at rated operating conditions. Mechanical durability is 6000 operations. Net dimensions are 372 mm height, 334.5 mm width, and 151.5 mm depth; net weight is 17.2 kg. Front degree of protection is IP00. Handle and shaft are not included, and no lock is provided. Manufacturer ID: 1SCA105637R1001.