- AF140-30-22-13
The ABB AF140-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 37 kW at 220/230/240 V, 75 kW at 380/400 V, 415 V, and 690 V, and 90 kW at 440 V and 500 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL447001R1322.
- AF140-30-22-14
The ABB AF140-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 200 A at 690 V and 40 °C, and 160 A at 690 V and 70 °C. AC-3 rated operational current is 140 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, and 80 A at 690 V and 55 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-22-31
ABB AF140-30-22-31 is an AC contactor with three normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 200 A at 690 V and 40 °C, 175 A at 60 °C, and 160 A at 70 °C. AC-3 rated operational current is 140 A at 415 V and 60 °C, and 80 A at 690 V and 60 °C. AC-3 rated operational power is 75 kW at 415 V and 37 kW at 220/230/240 V. Dimensions are 110 mm wide, 138.5 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-22-32
The ABB AF140-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 380/400 V and 415 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 380/400 V and 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 110 mm wide, 138.5 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-22-33
The ABB AF140-30-22-33 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-22-34
The ABB AF140-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 690 V in the main circuit at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; weight is 1.55 kg.
- AF140-30-22-42
The ABB AF140-30-22-42 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Manufacturer ID: 1SFL447001R4222.
- AF140-30-22-43
ABB AF140-30-22-43 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 220/230/240 V, 75 kW at 380/400 V and 415 V, 90 kW at 440 V and 500 V, and 75 kW at 690 V. Dimensions are 110 mm wide, 126 mm deep and 150 mm high; net weight 1.55 kg.