- AF140-30-22-33
The ABB AF140-30-22-33 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-22-34
The ABB AF140-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 690 V in the main circuit at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; weight is 1.55 kg.
- AF140-30-22-42
The ABB AF140-30-22-42 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Manufacturer ID: 1SFL447001R4222.
- AF140-30-22-43
ABB AF140-30-22-43 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 220/230/240 V, 75 kW at 380/400 V and 415 V, 90 kW at 440 V and 500 V, and 75 kW at 690 V. Dimensions are 110 mm wide, 126 mm deep and 150 mm high; net weight 1.55 kg.
- AF140-30-22B-11
The ABB AF140-30-22B-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, and 160 A at 690 V and 70 °C. AC-3 ratings include 140 A at 415 V and 55 °C, and 80 A at 690 V and 55 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF140-30-22B-12
The ABB AF140-30-22B-12 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF140-30-22B-13
The ABB AF140-30-22B-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V.
- AF140-30-22B-14
The ABB AF140-30-22B-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.3 kg.