- NFB44E-14
ABB NFB44E-14 intermediate relay with 4 NO and 4 NC auxiliary contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. Rated impulse withstand voltage is 6 kV. Control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, or DC. Dimensions are 45 mm wide, 86 mm deep, 86 mm high; net weight 0.37 kg. Screw terminals accept 0.75 to 2.5 mm². Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or by two M4 screws placed diagonally. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 61373, and applicable parts of IEC 60077-1, IEC 60077-2, and EN 50155.
- NFB44EK-14
The ABB NFB44EK-14 is an intermediate relay with manufacturer ID 1SBH137063R1444. It provides four auxiliary normally open contacts and four auxiliary normally closed contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Net dimensions are 45 mm width, 110.5 mm depth, 92.3 mm height, and 0.34 kg weight. Terminals are push-in spring type. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1 and IEC 60077-2 applicable parts, EN 50155 applicable parts, TR CU 001/2011, and IEC 61373.
- NFB62E-14
The ABB NFB62E-14 is an intermediate relay with manufacturer ID 1SBH137061R1462. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.37 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. It has six normally open and two normally closed auxiliary contacts. The rated control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Rated impulse withstand voltage is 6 kV. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- NFB62EK-14
The ABB NFB62EK-14 is an intermediate relay with manufacturer ID 1SBH137063R1462. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.33 kg. The contact arrangement is 6 auxiliary contacts NO and 2 auxiliary contacts NC. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- NFB80E-14
The ABB NFB80E-14 intermediate relay (manufacturer ID 1SBH137061R1480) has eight normally open auxiliary contacts and no normally closed auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.37 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Maximum mechanical switching frequency is 6000 cycles per hour. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715. Standards listed include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, and CSA C22.2 No. 60947-5-1.
- NFB80EK-14
ABB NFB80EK-14 intermediate relay, manufacturer ID 1SBH137063R1480. Rated operational voltage is 690 V for auxiliary and main circuits, with rated frequency 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 250 to 500 V at 50 Hz, 250 to 500 V at 60 Hz, and 250 to 500 V DC. The relay has 8 NO auxiliary contacts and no NC auxiliary contacts. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, weighing 0.33 kg. DIN-rail mounting is TH35-15 or TH35-7.5 per IEC 60715.
- NFB80ERT-14
The ABB NFB80ERT-14 intermediate relay (manufacturer ID 1SBH137060R1480) measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.37 kg. It provides 8 auxiliary contacts NO and 0 NC. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V under AC-15. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA; rated impulse withstand voltage is 6 kV. Maximum mechanical switching frequency is 6000 cycles per hour. DIN-rail mounting is TH35-15 or TH35-7.5 according to IEC 60715.
- NFBAC17016
ABB spare part, manufacturer ID NFBAC17016, described in the supplied data as SCR PAN HD-B ST. The product type and frame size are listed as Spare_Parts. No ABB type designation is supplied. Product net weight is 0 kg and gross weight is 0 kg, with a gross volume of 0 in³. The item is not made to order and is not quote only. Order multiple is 1 EA. Stocked at Wickliffe, Ohio, United States. No technical ratings, standards, certifications, or compatibility information are provided in the source data.