- CA5-13M
The ABB CA5-13M is a front-mounted auxiliary contact block with screw terminals. It provides 1 normally open (NO) and 3 normally closed (NC) auxiliary contacts. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated operational current DC-13 is 6 A / 144 W at 24 V and 0.3 A / 75 W at 250 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals offer IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529. Net dimensions are 43 mm width, 39 mm depth, and 47 mm height; net weight is 0.06 kg.
- CA5-13N
ABB CA5-13N auxiliary contact block, manufacturer ID 1SBN010040R1213. It provides 1 normally open and 3 normally closed auxiliary contacts with screw terminals. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.30 A / 66 W at 220 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Dimensions are 43 mm width, 39 mm depth, 47 mm height, and 0.06 kg net weight. Auxiliary terminals have IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-22E
ABB CA5-22E auxiliary contact block, manufacturer ID 1SBN010040R1022. It provides 2 normally open and 2 normally closed auxiliary contacts with screw terminals. Dimensions are 44 mm width, 39 mm depth, and 47 mm height; net weight 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.30 A / 66 W at 220 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Maximum electrical switching frequency is 1200 cycles per hour; maximum mechanical switching frequency is 3600 cycles per hour.
- CA5-22E-AU
The ABB CA5-22E-AU is a front-mounted auxiliary contact block with two normally open and two normally closed contacts. It uses screw terminals and measures 43 mm wide, 39 mm deep, and 47 mm high, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V and 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.3 A / 75 W at 250 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals provide IP20 protection per IEC 60529, IEC 60947-1, and EN 60529.
- CA5-22ERT
The ABB CA5-22ERT is a front-mount auxiliary contact block with 2 NO and 2 NC auxiliary contacts. It measures 43 mm wide, 39 mm deep, and 47 mm high, and weighs 0.06 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Terminals are ring-tongue type.
- CA5-22M
The ABB CA5-22M is a front-mounted auxiliary contact block with two normally open and two normally closed contacts. It uses screw terminals and measures 44 mm wide, 39 mm deep, and 47 mm high, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with AC-15 ratings from 6 A at 24/127 V to 2 A at 500/690 V, and DC-13 ratings from 6 A at 24 V to 0.3 A at 250 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Maximum electrical switching frequency is 1200 cycles per hour; mechanical durability is 10 million operations. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Suitable for A9, A12, A16, A26, A30, A40, AL9, AL9Z, AL12, AL12Z, AL16, AL16Z, AL26, AL30, AL40, TAL9, TAL12, TAL16, TAL26, TAL30, TAL40, UA16, UA26, and UA30.
- CA5-22M-AU
ABB CA5-22M-AU auxiliary contact block, manufacturer ID 1SBN010043R1122. It provides 2 normally open and 2 normally closed instantaneous auxiliary contacts with screw terminals. Auxiliary circuit ratings: 690 V rated operational voltage, 50/60 Hz, AC-15 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, 2 A at 500 V and 690 V; DC-13 6 A/144 W at 24 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Short-circuit protection uses gG fuses, 10 A. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Dimensions: 43 mm width, 39 mm depth, 47 mm height; net weight 0.06 kg. Suitable for A9 through A40, AL9 through AL40, and TAL9 through TAL40.
- CA5-22MRT
The ABB CA5-22MRT is a front-mounted auxiliary contact block with four poles: two normally open (NO) and two normally closed (NC) auxiliary contacts. It uses ring-tongue screw terminals. Dimensions are 43 mm width, 39 mm depth, and 47 mm height, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Suitable for A9 through A40, AL9 through AL40, and TAL9 through TAL40.