- AF146-30-00B-33
The ABB AF146-30-00B-33 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its manufacturer ID is 1SFL467002R3300. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF146-30-00B-34
The ABB AF146-30-00B-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Manufacturer ID: 1SFL467002R3400.
- AF146-30-00B-42
The ABB AF146-30-00B-42 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-00B-43
The ABB AF146-30-00B-43 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 380/400 V and 415 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 380/400 V and 415 V, 90 kW at 440 V, 500 V, and 690 V, and 45 kW at 220/230/240 V.
- AF146-30-11-11
The ABB AF146-30-11-11 is a non-reversing, 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It is rated for a main circuit of 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V. Corresponding AC-3 power ratings include 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF146-30-11-12
The ABB AF146-30-11-12 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, and 93 A at 690 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-11-13
The ABB AF146-30-11-13 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-11-14
The ABB AF146-30-11-14 is a non-reversing 3-pole AC contactor with an electronically controlled coil. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO plus 1 auxiliary contact NC. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL467001R1411.