- AF146-30-11-13
The ABB AF146-30-11-13 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-11-14
The ABB AF146-30-11-14 is a non-reversing 3-pole AC contactor with an electronically controlled coil. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO plus 1 auxiliary contact NC. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Manufacturer ID: 1SFL467001R1411.
- AF146-30-11-31
ABB AC contactor AF146-30-11-31, manufacturer ID 1SFL467001R3111. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 60 °C, 130 A at 500 V and 60 °C, 93 A at 690 V and 60 °C, and 60 A at 1000 V and 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high; weight is 1.55 kg.
- AF146-30-11-32
The ABB AF146-30-11-32 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF146-30-11-33
The ABB AF146-30-11-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Rated making capacity AC-3 is 10 x Ie AC-3; rated breaking capacity AC-3 is 8 x Ie AC-3.
- AF146-30-11-34
ABB AF146-30-11-34 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; weight is 1.55 kg. Manufacturer ID 1SFL467001R3411.
- AF146-30-11-42
The ABB AF146-30-11-42 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF146-30-11-43
ABB AC contactor, display model AF146-30-11-43, manufacturer ID 1SFL467001R4311. It has three normally open main contacts, no normally closed main contacts, and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.55 kg.