- AF1350T-30-11 230-240V 50/60Hz
The ABB AF1350T-30-11 230-240V 50/60Hz is an AC contactor with three main normally open contacts and no main normally closed contacts, plus two auxiliary normally open and two auxiliary normally closed contacts. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current of 1350 A according to IEC 60947-4-1 at 40 °C for open contactors. Rated operational current AC-1 is 1350 A at 1000 V and 40 °C, 1150 A at 55 °C, and 1000 A at 70 °C. AC-3 rated operational power includes 475 kW at 380/400 V and 257 kW at 220/230/240 V. The coil is rated 230 to 240 V at 50 Hz, 60 Hz, and DC operation. Dimensions are 438 mm wide, 244 mm deep, and 392 mm high, with a net weight of 32 kg.
- AF140
ABB AF140 is an industrial catalog item. Key specifications include Number of Batteries: 0, Product Net Width: 86 mm, Product Net Height: 38 mm, and Product Net Depth / Length: 86 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AF140-30-00-11
The ABB AF140-30-00-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-00-12
The ABB AF140-30-00-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 130 A at 500 V, and 80 A at 690 V, all at 55 °C. Corresponding AC-3 rated operational power is 37 kW at 220/230/240 V, 75 kW at 380/400 V, 415 V, and 690 V, and 90 kW at 440 V and 500 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-00-13
The ABB AF140-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its coil accepts a rated control circuit voltage of 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. The main circuit is rated 690 V and 50/60 Hz, with AC-3 ratings of 140 A at 415 V and 75 kW at 415 V. Conventional free-air thermal current is 200 A per IEC 60947-4-1 at 40 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Mechanical durability is 5 million operating cycles. The contactor uses double-clamp terminals and is classified as ETIM EC000066.
- AF140-30-00-14
The ABB AF140-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, and 160 A at 690 V and 70 °C. AC-3 ratings include 140 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, and 80 A at 690 V and 55 °C. AC-3 rated operational power includes 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-00-31
The ABB AF140-30-00-31 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-00-32
ABB AF140-30-00-32 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 at an open-contactor ambient of 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high; net weight is 1.55 kg.